High failure rate for an epicardial implantable cardioverter-defibrillator lead: implications for long-term follow-up of patients with an implantable cardioverter-defibrillator.

نویسندگان

  • P A Brady
  • P A Friedman
  • J M Trusty
  • S Grice
  • S C Hammill
  • M S Stanton
چکیده

OBJECTIVES The purpose of this study was to determine the risk of epicardial lead failure during long-term follow-up and its mode of presentation. BACKGROUND Despite the high prevalence of epicardial lead-based implantable cardioverter-defibrillators, their long-term performance is unknown, and appropriate follow-up has not been established. METHODS The study group comprised all patients in whom an epicardial lead system was implanted at the Mayo Clinic between October 31, 1984 and November 3, 1994. The number of lead fractures and leads with fluid within the insulation and the mode of presentation were determined retrospectively by review of patient visits, radiographs of lead systems and data derived from formal lead testing. RESULTS At 4 years, the survival rate free of lead malfunction, using formal lead testing, for 160 Medtronic epicardial patches (models 6897 and 6921) was 72% compared with 92.5% for the 179 Cardiac Pacemaker, Inc. (CPI) patches (models 0040 and 0041) (p = 0.01). In addition, five Medtronic patches in three patients had fluid within the lead insulation but no obvious fracture. No CPI patches had fluid identified within the leads. Of 330 Medtronic epicardial pace/sense leads (model 6917), the 4-year survival rate free of lead malfunction as assessed by lead testing was 96%. In all, 19 presentations of lead malfunction were found in 17 patients (2 patients had more than one lead fracture at different times). In 11 (58%) of these presentations, the patients were asymptomatic despite the presence of obvious lead fracture. CONCLUSIONS Epicardial lead malfunction is common on long-term follow-up, and some leads have a failure rate of 28% at 4 years. Many patients with fractured leads remain asymptomatic, despite involvement of multiple leads in some cases. Therefore, consideration should be given to regular periodic lead testing in addition to routine X-ray examination, as asymptomatic lead malfunction can present with normal chest X-ray findings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.

BACKGROUND The number of patients with longer follow-up after implantation of an implantable cardioverter-defibrillator is increasing continuously. Defibrillation lead failure is a typical long-term complication. Therefore, the long-term reliability of implantable cardioverter-defibrillator leads has become an increasing concern. The aim of the present study was to assess the annual rate of tra...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

How much scrutiny and stress can the Fidelis lead withstand?

The implantable cardioverter-defibrillator lead has undergone numerous design and manufacturing changes over the last 25 years aimed at improving patient care and outcomes. It is widely accepted that implantable cardioverterdefibrillator leads, similar to pacemaker leads, have a finite life. The design of an implantable cardioverter-defibrillator lead is more complex than that of a pacemaker le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 1998