Estimation efficiency and statistical power in arterial spin labeling fMRI.
نویسندگان
چکیده
Arterial spin labeling (ASL) data are typically differenced, sometimes after interpolation, as part of preprocessing before statistical analysis in fMRI. While this process can reduce the number of time points by half, it simplifies the subsequent signal and noise models (i.e., smoothed box-car predictors and white noise). In this paper, we argue that ASL data are best viewed in the same data analytic framework as BOLD fMRI data, in that all scans are modeled and colored noise is accommodated. The data are not differenced, but the control/label effect is implicitly built into the model. While the models using differenced data may seem easier to implement, we show that differencing models fit with ordinary least squares either produce biased estimates of the standard errors or suffer from a loss in efficiency. The main disadvantage to our approach is that non-white noise must be modeled in order to yield accurate standard errors, however, this is a standard problem that has been solved for BOLD data, and the very same software can be used to account for such autocorrelated noise.
منابع مشابه
Analysis and design of perfusion-based event-related fMRI experiments.
Perfusion-based functional magnetic resonance imaging (fMRI) using arterial spin labeling (ASL) methods has the potential to provide better localization of the functional signal to the sites of neural activity compared to blood oxygenation level-dependent (BOLD) contrast fMRI. At present, experiments using ASL have been limited to simple block and periodic single-trial designs. We present here ...
متن کاملQuantitative basal CBF and CBF fMRI of rhesus monkeys using three-coil continuous arterial spin labeling.
A three-coil continuous arterial-spin-labeling technique with a separate neck labeling coil was implemented on a Siemens 3T Trio for quantitative cerebral blood flow (CBF) and CBF fMRI measurements in non-human primates (rhesus monkeys). The optimal labeling power was 2 W, labeling efficiency was 92+/-2%, and optimal post-labeling delay was 0.8 s. Gray matter (GM) and white matter (WM) were seg...
متن کاملEmpirical analyses of null-hypothesis perfusion FMRI data at 1.5 and 4 T.
Functional magnetic resonance imaging (fMRI) based on arterial spin labeling (ASL) perfusion contrast is an emergent methodology for visualizing brain function both at rest and during task performance. Because of the typical pairwise subtraction approach in generating perfusion images, ASL contrast manifests different noise properties and offers potential advantages for some experimental design...
متن کاملTo smooth or not to smooth? ROC analysis of perfusion fMRI data.
Blood oxygenation level dependent (BOLD) contrast has been widely used for visualizing regional neural activation. Temporal filtering and parameter estimation algorithms are generally used to account for the intrinsic temporal autocorrelation present in BOLD data. Arterial spin labeling perfusion imaging is an emerging methodology for visualizing regional brain function both at rest and during ...
متن کاملA signal processing model for arterial spin labeling functional MRI.
A model of the signal path in arterial spin labeling (ASL)-based functional magnetic resonance imaging (fMRI) is presented. Three subtraction-based methods for forming a perfusion estimate are considered and shown to be specific cases of a generalized estimate consisting of a modulator followed by a low pass filter. The performance of the methods is evaluated using the signal model. Contaminati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2006