Evaluation of sensitivity of two serological tests for diagnosing pneumonia caused by Legionella pneumophila serogroup 1.

نویسندگان

  • T G Harrison
  • E Dournon
  • A G Taylor
چکیده

The sensitivity of an indirect immunofluorescence antibody test (IFAT) and a rapid microagglutination test (RMAT) for the diagnosis of Legionnaires' disease caused by Legionella pneumophila serogroup 1 was evaluated using serum specimens from 119 patients with bacteriologically confirmed infections. The sensitivity of both assays was found to be about 80%. In addition, antibody titres suggestive of L pneumophila infection were found in 40% of patients in the first week after admission to hospital. These data show that both assays can be used with confidence in the early diagnosis of Legionnaires' disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isolation of Legionella pneumophila serogroup 14 from a human source.

A strain of Legionella pneumophila serogroup 14 was isolated during a retrospective study, after death from the sputum of a patient who had had acute leukaemia and pneumonia. This is the third strain of that serogroup to be isolated from a human source. This event emphasises the importance of performing culture as well as serological tests, so as to detect cases of legionellosis caused by strai...

متن کامل

Legionella pneumonia due to non-Legionella pneumophila serogroup 1: usefulness of the six-point scoring system

BACKGROUND Because of a limited number of reports, we aimed to investigate the clinical characteristics of patients with Legionella pneumonia due to non-Legionella pneumophila serogroup 1 and the diagnostic usefulness of the six-point scoring system for such patients compared with patients with pneumonia caused by L. pneumophila serogroup 1. METHODS We retrospectively analysed patients diagno...

متن کامل

Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report

BACKGROUND Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE PRESENTATION We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic emplo...

متن کامل

Legionella pneumophila serogroup 12 isolated from human and environmental sources.

A Legionella-like organism (strain 570-CO-H [= ATCC 43290]) isolated from the lung tissue of a patient with pneumonia was shown by growth, as well as physiological, serological, and genetic characteristics, to belong to a new Legionella pneumophila serogroup, serogroup 12. Two additional strains were detected with antiserum specific for strain 570-CO-H. These strains were isolated from environm...

متن کامل

Legionella pneumophila cases in a community hospital: A 12-month retrospective review

BACKGROUND Legionella pneumonia has long been recognized as an important cause of community-acquired pneumonia associated with significant morbidity and mortality; however, the description of the incidence of this disease is restricted to sporadic cases in the literature. With the advent of an inexpensive and rapid urine antigen test, routine testing has become more common. We report findings o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 1987