A simplified liquid chromatography-mass spectrometry assay for artesunate and dihydroartemisinin, its metabolite, in human plasma.

نویسندگان

  • Paktiya Teja-Isavadharm
  • Duangsuda Siriyanonda
  • Raveewan Siripokasupkul
  • Roongnapa Apinan
  • Nitima Chanarat
  • Apassorn Lim
  • Srisombat Wannaying
  • David Saunders
  • Mark M Fukuda
  • Robert S Miller
  • Peter J Weina
  • Victor Meléndez
چکیده

Artesunate (AS) is a potent antimalarial that is used worldwide for the treatment of malaria. A simple method with a total run time of 12 min was developed and validated for the quantification of AS and dihydroartemisinin (DHA), its active metabolite, in human (heparinized) plasma based on one-step protein precipitation in acetonitrile using artemisinin (ARN) as an internal standard, followed by liquid chromatography with a single quadrupole mass spectrometry system connected to a C18 column. Peak area ratio responses were fitted to the 2nd-order curve type, polynomial equation with weighting (1/concentration) over a quantification range between 3.20/5.33-3,000/5,000 nM (1.23/1.52-1153/1422 ng/mL) of AS/DHA showing linearity with very good correlation (r2>0.999). Single ion recordings of 5 µL injections of plasma extracts allowed for limits of detection of 1.02 nM (0.39 ng/mL) for AS and 0.44 nM (0.13 ng/mL) for DHA. The inter-assay and intra-assay accuracy and precision of the method was very good with an inaccuracy of ±12.4% and coefficients of variation of ≤10.7% at all tested concentrations. The recovery of the analytes from plasma was ≥95%. Other commonly used antimalarials including mefloquine, quinine, and chloroquine, did not interfere with the analysis. Post-preparative tests over 24 h in an autosampler (10 °C) showed that the DHA response was only 2.1% of AS from auto-hydrolysis, and β-DHA was the major, stable epimer that was used for quantification of DHA. In contrast, α-DHA increased steadily up to 600%. Artesunate and DHA in plasma were stable through three freeze/thaw cycles for up to 6 h at room temperature and up to one year at -80 °C.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Quantification of Artemether and its Active Metabolite Dihydroartemisinin in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry

A sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of artemether (ART) and its active metabolite dihydroartemisinin (DHA) in human plasma using artemisinin (ARM) as the internal standard (IS). The analytes were extracted by liquid-liquid extraction and chromatographic separation was ach...

متن کامل

Pharmacokinetic parameters of artesunate and dihydroartemisinin in rats infected with Fasciola hepatica.

OBJECTIVES The pharmacokinetic (PK) parameters of artesunate, recently discovered to possess promising trematocidal activity, and its main metabolite dihydroartemisinin (DHA) were determined in rats infected with hepatic and biliary stages of Fasciola hepatica and compared with uninfected rats after single intragastric and intravenous (iv) doses. METHODS Rats infected with F. hepatica for 25 ...

متن کامل

Development and Application of a Validated Liquid Chromatography-Mass Spectrometry Method for the Determination of Dexchlorpheniramine Maleate in Human Plasma

     A convenient liquid chromatographic-single Quadrupole mass spectrometric (LC-MS) method was developed and validated for dexchlorpheniramine maleate (INN name: chlorphenamine) determination in human plasma. The need for just a single liquid-liquid extraction with ethyl acetate and being highly sensitive were the advantages of this method. The linearity was also excellent over the range of 1...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Molecules

دوره 15 12  شماره 

صفحات  -

تاریخ انتشار 2010