Survey of terminology used for the intraoperative direction of C-arm fluoroscopy.

نویسندگان

  • Elliott Pally
  • Hans J Kreder
چکیده

BACKGROUND Orthopedic surgeons depend on the intraoperative use of fluoroscopy to facilitate procedures across all subspecialties. The versatility of the C-arm fluoroscope allows acquisition of nearly any radiographic view. This versatility, however, creates the opportunity for difficulty in communication between surgeon and radiation technologist. Poor communication leads to delays, frustration and increased exposure to ionizing radiation. There is currently no standard terminology employed by surgeons and technologists with regards to direction of the fluoroscope. METHODS The investigation consisted of a web-based survey in 2 parts. Part 1 was administered to the membership of the Canadian Orthopedic Association, part 2 to the membership of the Canadian Association of Medical Radiation Technologists. The survey consisted of open-ended or multiple-choice questions examining experience with the C-arm fluoroscope and the terminology preferred by both orthopedic surgeons and radiation technologists. RESULTS The survey revealed tremendous inconsistency in language used by orthopedic surgeons and radiation technologists. It also revealed that many radiation technologists were inexperienced in operating the fluoroscope. CONCLUSION Adoption of a common language has been demonstrated to increase efficiency in performing defined tasks with the fluoroscope. We offer a potential system to facilitate communication based on current terminology used among Canadian orthopedic surgeons and radiation technologists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"Turn laterally to the left!". The need for uniform C-arm communication terminology during orthopaedic trauma surgery.

To avoid disturbed teamwork, unnecessary radiation exposure, and procedural delays, we designed and tested a uniform communication language for use in fluoroscopy-assisted surgical procedures. Input of surgeons and radiographers was used to create a set of commands. The potential benefit of this terminology was explored in an experimental setting. There was a tremendous diversity in the current...

متن کامل

Surgeon, staff, and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion: impact of 3D fluoroscopy-based navigation partially replacing conventional fluoroscopy: study protocol for a randomized controlled trial

BACKGROUND Some symptomatic degenerative conditions of the lumbar spine may be treated with spinal fusion if conservative treatment has failed. The minimally invasive technique of transforaminal lumbar interbody fusion (MIS TLIF) is increasingly used but has been found to generate increased radiation exposure to the patient and staff. Modern three-dimensional (3D) C-arm devices are capable of p...

متن کامل

Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum

Percutaneous screw insertion for minimally displaced or reducible acetabular fracture using x-ray fluoroscopy and computer-assisted navigation system has been advocated by some authors. The purpose of this study was to compare intraoperative conditions and clinical results between isocentric C-arm 3-dimensional (Iso-C 3D) fluoroscopy and conventional fluoroscopy for percutaneous retrograde scre...

متن کامل

Complication Avoidance and Management Using the O-arm for Odontoid Screw Fixation: Technical Note

Objective: Odontoid screw fixation is an accepted surgical approach for Type 2 odontoid fractures with an intact transverse ligament. Typically, intraoperative bi-planar flouroscopy is used for placement of an odontoid screw. However, the quality of the images obtained with bi-planar fluoroscopy in the operating room is variable (due to patient body habitus) and screws may be misplaced. We repo...

متن کامل

Dosimetric pitfalls in the application of shielding disk in breast intraoperative electron radiation therapy

Introduction: Intraoperative electron radiotherapy (IOERT) is an IORT technique in which electron beams with different nominal energies are used for irradiation of microscopic residual of tumor bed after surgery. Application of a shielding disk, which is positioned under the target volume, for protecting the normal tissues such as pectoral muscle, lung, and heart is one of the a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of surgery. Journal canadien de chirurgie

دوره 56 2  شماره 

صفحات  -

تاریخ انتشار 2013