PURPOSE To investigate prostatic organ motion at both setup and intrafraction using an onboard image-guided system. An intrafraction field-based repositioning method also was evaluated. MATERIALS AND METHODS A dual fluoroscopy with amorphous-silicon flat panel (DFFP) system was used for the three-dimensional registration of implanted markers in the prostate of eight organ-confined cancer patients planned for treatment with intensity modulated radiation therapy (IMRT). Day-to-day motion errors were quantified and intrafraction displacements of more than +/-1 mm were corrected. RESULTS Among 214 fractions and 565 system views, day-to-day mean magnitude of marker discrepancy +/- standard deviation (SD) was 1.76 +/- 1.4 mm, 3.14 +/- 1.6 mm, and 3.78 +/- 2.4 mm in the right-left, cranial-caudal, and anterior-posterior directions, respectively. The intrafractional mean magnitude +/- SD of marker displacement was 0.45 +/- 0.7 mm, 1.08 +/- 1.38 mm and 1.45 +/- 1.70 mm in the right-left, cranial-caudal, and anterior-posterior directions, respectively. Intrafraction corrected sessions (84/214) showed a median (range) of motion of 0.1 mm (-1.2 to 0.7 mm), -0.2 mm (-2.1 to 1.1 mm), and -0.2 mm (-1.7 to 2.0 mm) in the right-left, cranial-caudal, and anterior-posterior directions, respectively. CONCLUSION Motion uncertainty can be considerably decreased with daily use of the DFFP system. Reduced intrafraction organ motion clearly endorsed the value of the repositioning approach, allowing a safer dose escalation protocol.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Image Guided Radiation Therapy

Volumetric imaging and planning for 3-D conformal RT and IMRT have pressured the oncology community to better understand the geometric uncertainties inherent in the RT delivery process, including set-up error (inter-fraction) as well as organ motion during treatment (intra-fraction). This has ushered in the development of emerging technologies and clinical processes collectively referred to as ...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiation medicine

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 2005