Dark-blood late gadolinium enhancement without additional magnetization preparation

نویسندگان

  • Robert J Holtackers
  • Amedeo Chiribiri
  • Torben Schneider
  • David M Higgins
  • René M Botnar
چکیده

BACKGROUND This study evaluates a novel dark-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) method, without using additional magnetization preparation, and compares it to conventional bright-blood LGE, for the detection of ischaemic myocardial scar. LGE is able to clearly depict myocardial infarction and macroscopic scarring from viable myocardium. However, due to the bright signal of adjacent left ventricular blood, the apparent volume of scar tissue can be significantly reduced, or even completely obscured. In addition, blood pool signal can mimic scar tissue and lead to false positive observations. Simply nulling the blood magnetization by choosing shorter inversion times, leads to a negative viable myocardium signal that appears equally as bright as scar due to the magnitude image reconstruction. However, by combining blood magnetization nulling with the extended grayscale range of phase-sensitive inversion-recovery (PSIR), a darker blood signal can be achieved whilst a dark myocardium and bright scar signal is preserved. METHODS LGE was performed in nine male patients (63 ± 11y) using a PSIR pulse sequence, with both conventional viable myocardium nulling and left ventricular blood nulling, in a randomized order. Regions of interest were drawn in the left ventricular blood, viable myocardium, and scar tissue, to assess contrast-to-noise ratios. Maximum scar transmurality, scar size, circumferential scar angle, and a confidence score for scar detection and maximum transmurality were also assessed. Bloch simulations were performed to simulate the magnetization levels of the left ventricular blood, viable myocardium, and scar tissue. RESULTS Average scar-to-blood contrast was significantly (p < 0.001) increased by 99% when nulling left ventricular blood instead of viable myocardium, while scar-to-myocardium contrast was maintained. Nulling left ventricular blood also led to significantly (p = 0.038) higher expert confidence in scar detection and maximum transmurality. No significant changes were found in scar transmurality (p = 0.317), normalized scar size (p = 0.054), and circumferential scar angle (p = 0.117). CONCLUSIONS Nulling left ventricular blood magnetization for PSIR LGE leads to improved scar-to-blood contrast and increased expert confidence in scar detection and scar transmurality. As no additional magnetization preparation is used, clinical application on current MR systems is readily available without the need for extensive optimizations, software modifications, and/or additional training.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Black blood late gadolinium enhancement using combined T2 magnetization preparation and inversion recovery

Background Late gadolinium enhancement (LGE) imaging allows assessment of focal scar [1]. An inversion recovery based sequence is commonly used to achieve suppression of healthy myocardium signal. However, the blood pool and subendocardial scar typically have similar signal, making it difficult to distinguish subendocardial scar. Several methods have been proposed to increase the blood-scar con...

متن کامل

Dark blood Late Gadolinium Enhancement improves conspicuity of ablation lesions

Background Cardiac MR has begun to be utilized for imaging ablation lesions. Peri-procedural imaging could potentially be used to guide therapy, but this application has unique requirements and limitations. In peri-procedural imaging of acute lesions, subjects are frequently sedated and imaging should be conducted free-breathing. Furthermore, Late Gadolinium Enhancement (LGE) imaging of sub-end...

متن کامل

Comparison of T2-preparation and magnetization-transfer preparation for black blood delayed enhancement

Background A fundamental component of the CMR exam is contrast enhanced imaging, which is crucial for delineating diseased from normal tissue. Unfortunately, diseased tissue immediately adjacent to blood often is hidden since there is poor contrast between hyperenhanced tissue and bright blood. A new method recently described, Flow-Independent Dark-blood DeLayed Enhancement technique (FIDDLE), ...

متن کامل

Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar

BACKGROUND Conventional bright blood late gadolinium enhancement (bright blood LGE) imaging is a routine cardiovascular magnetic resonance (CMR) technique offering excellent contrast between areas of LGE and normal myocardium. However, contrast between LGE and blood is frequently poor. Dark blood LGE (DB LGE) employs an inversion recovery T2 preparation to suppress the blood pool, thereby incre...

متن کامل

Accuracy of a prototype dark blood late gadolinium enhancement technique for the detection and quantification of myocardial infarction

Background Conventional inversion recovery (IR) techniques for the detection of late gadolinium enhancement (LGE) in the myocardium are bright blood methods in which the signal in the blood chamber is often similar to the signal in hyperenhanced irreversibly damaged myocardial areas. Due to the low contrast to noise ratio (CNR) between blood and the hyperenhanced myocardium at the tissue-blood ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2017