Computed tomography of cryogenic biological specimens based on X-ray microscopic images.

نویسندگان

  • D Weiss
  • G Schneider
  • B Niemann
  • P Guttmann
  • D Rudolph
  • G Schmahl
چکیده

Soft X-ray microscopy employs the photoelectric absorption contrast between water and protein in the 2.34-4.38 nm wavelength region to visualize protein structures down to 30 nm size without any staining methods. Due to the large depth of focus of the Fresnel zone plates used as X-ray objectives, computed tomography based on the X-ray microscopic images can be used to reconstruct the local linear absorption coefficient inside the three-dimensional specimen volume. High-resolution X-ray images require a high specimen radiation dose, and a series of images taken at different viewing angles is needed for computed tomography. Therefore, cryo microscopy is necessary to preserve the structural integrity of hydrated biological specimens during image acquisition. The cryo transmission X-ray microscope at the electron storage ring BESSY I (Berlin) was used to obtain a tilt series of images of the frozen-hydrated green alga Chlamydomonas reinhardtii. The living specimens were inserted into borosilicate glass capillaries and, in this first experiment, rapidly cooled by plunging into liquid nitrogen. The capillary specimen holders allow image acquisition over the full angular range of 180 degrees. The reconstruction shows for the first time details down to 60 nm size inside a frozen-hydrated biological specimen and conveys a clear impression of the internal structures. This technique is expected to be applicable to a wide range of biological specimens, such as the cell nucleus. It offers the possibility of imaging the three-dimensional structure of hydrated biological specimens close to their natural living state.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

High-resolution computed tomography with a compact soft x-ray microscope.

Computed tomography based on high-resolution soft x-ray microscopy utilizes the natural contrast for biological specimens provided by the water window (lambda = 2.4 - 4.4 nm) and the high resolving power of zone plate objectives. It is capable of revealing the 3D structure of biological specimens at sub-visible-microscopic resolution. To date, the technique has only been available at synchrotro...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Specimen preparation for cryogenic coherent X-ray diffraction imaging of biological cells and cellular organelles by using the X-ray free-electron laser at SACLA

Coherent X-ray diffraction imaging (CXDI) allows internal structures of biological cells and cellular organelles to be analyzed. CXDI experiments have been conducted at 66 K for frozen-hydrated biological specimens at the SPring-8 Angstrom Compact Free-Electron Laser facility (SACLA). In these cryogenic CXDI experiments using X-ray free-electron laser (XFEL) pulses, specimen particles dispersed...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultramicroscopy

دوره 84 3-4  شماره 

صفحات  -

تاریخ انتشار 2000