The Development and Evaluation of a 3 - Dimensional , Image - Based , Patient - Specific , Dynamic Model of

نویسنده

  • Carl William Imhauser
چکیده

The Development and Evaluation of a 3-Dimensional, Image-Based, Patient-Specific, Dynamic Model of the Hindfoot Carl William Imhauser Sorin Siegler, Ph.D. This study developed subject-specific, three-dimensional dynamic hindfoot models (1 in vivo, 1 in vitro) using 3D stress MRI data. Each model’s ability to capture mechanical phenomena including those of the healthy hindfoot and the hindfoot with ligament injury was evaluated through subject-specific experimental mechanical analyses (using an arthrometer and a stress MRI technique). Existing software (3DVIEWNIX) was incorporated with software developed in-house (marching cubes program) to obtain the subject’s bone surface geometry, collateral and subtalar ligament insertion data. The bone surface data were then imported into a reverse engineering software package (Geomagic Studio) to obtain CAD representations for the bone geometries. The ligaments’ non-linear structural properties were obtained directly from an existing experimental study or were estimated. Contact forces between bones were modeled using cartilage’s Elastic Modulus and an exponential term to imitate its nonlinear compression characteristics. The ADAMS 2003 dynamic simulation software generated and solved the dynamic equations of motion under the forcing functions and boundary conditions. The in vivo experimental kinematic data were smaller than those predicted by the model. This indicates that surrounding soft tissues excluding the ligaments may decrease joint range of motion. The in vitro model captured the experimental kinematic patterns of the ankle joint complex, but did so by under-estimating ankle joint motion and overestimating subtalar joint motion. Better knowledge of the ankle joint and subtalar joint ligament structural properties is necessary. Similar to experimental data, the in vivo and in vitro models’ ankle joint complex had non-linear load-displacement properties in all directions. They are dependent on the contact of the articulating surfaces and ligament constraints. Sensitivity analyses indicated that kinematic changes caused by altering ligament geometry are smaller than changes caused by lateral ligament removal; therefore the model may be sensitive to predicting the changes that occur during ligament rupture. The models’ assumptions and limitations include differences between the experimental and modeled boundary conditions, exclusion of the cartilage geometry, estimation of the contact damping coefficient, the contact stiffness and penetration exponent, estimation of the subtalar ligaments’ structural properties, generalized nonlinear properties for the collateral ligaments, and soft-tissue motion during the experiments. Future work must focus on developing a larger group of patient-specific models so that the output data has sufficient statistical power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Security, confidentiality, and privacy of information in the field of health with data EPR embedding in medical MRI images based on HVS model

the development of new technology and modern equipment has led to the development of telemedicine systems. As a result, there are dangers such as publishing patient information and intentionally or unintentionally, medical information. The forensic organization, as one of the powerful arms of the judiciary, pursues important cases in the medical and psychiatric commissions to take steps to rea...

متن کامل

Calculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model

Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...

متن کامل

Development and implementation of a Monte Carlo frame work for evaluation of patient specific out- of - field organ equivalent dose

Background: The aim of this study was to develop and implement a Monte Carlo framework for evaluation of patient specific out-of-field organ equivalent dose (OED). Materials and Methods: Dose calculations were performed using a Monte Carlo-based model of Oncor linac and tomographic phantoms. Monte Carlo simulations were performed using EGSnrc user codes. Dose measurements were performed using r...

متن کامل

New Dynamic Balancing System Based on Magnetic Interaction and Software Removal of some Perturbations

The purpose of this paper is to present a new type of dynamic balancing system, having a driving solution of the rotating part based on magnetic interactions. The magnetic system also plays the role of an elastic bearing. In the first part of the article is presented the technical solution which allows the dynamic balancing evaluation depending on the radial displacement between two disks with ...

متن کامل

Development and Evaluation of a Real Time Site-Specific Inter-Row Weed Management System

ABSTRACT- A real-time, site-specific, machine-vision based, inter-row patch herbicide application system was developed and evaluated. The image resolution was 640 × 480 pixels covering a total area of 350 mm x 240 mm of a field composed of four quadrants of 350 mm x 60 mm each. The image frames were processed by LabView® and MatLab®. The developed algorithm, based on weed coverage ratio and seg...

متن کامل

Evaluation of 2-D Aeroelastic Models Based on Indicial Aerodynamic Theory and Vortex Lattice Method in Flutter and Gust Response Determination

Two 2-D aeroelastic models are presented here to determine instability boundary (flutter speed) and gust response of a typical section airfoil with degrees of freedom in pitch and plunge directions. To build these 2-D aeroelastic models, two different aerodynamic theories including Indicial Aerodynamic Theory and Vortex Lattice Method (VLM) have been employed. Also, a 3-D aeroelastic framework ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004