Effect of hematocrit value upon electromagnetic flowmeter sensitivity.

نویسندگان

  • J Dennis
  • D G Wyatt
چکیده

An electromagnetic flowmeter system that has an accuracy of 0.1% and is insensitive to fluid conductivity was used to study the sensitivity to steady flow of a 6-mm cannular transducer. All measurements were carried out at 37°C. Sensitivity decreased with increasing hematocrit value whether flow was laminar or otherwise. With laminar flow and a given hematocrit value, the sensitivity also decreased with increasing flow rate. Sensitivity started to rise when increasing flow rate caused departure from the laminar regime. At the lowest flow used in the laminar regime (250 ml/min), the sensitivity fell 4% when the hematocrit value was changed from 0 to 66%; at 39.5% the reduction in sensitivity was 2%. With laminar flow at hematocrit 39.5% the sensitivity fell 1% as flow increased from 250 to 1500 ml/min. At hematocrit 29.5% the sensitivity rose 1.2% when the flow regime changed from laminar to turbulent. The changes may be explained in terms of a radial distribution of cells, of which a cell-free boundary layer is a particular example. Theoretical calculations show that the thickness of an apparent cell-free boundary layer must be tens of microns to explain the observations with laminar flow and that the apparent thickness is greatly reduced with onset of turbulence. A possible mechanism is described by which the results could be explained in terms of cell orientation. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Circuit Design and its Experimental Analysis for Electromagnetic Flowmeter in Measurement of Sewage

There are many problems in the traditional electromagnetic flowmeter. The problems involve three aspects. The first one is that the measurement precision is low. The second one is that the measurement range is narrow. The third one is that the test results are susceptible to interference. For the problems a new electromagnetic flowmeter controlled by single-chip microcomputer has been proposed....

متن کامل

The influence of wellbore inflow on electromagnetic borehole flowmeter measurements.

This paper describes a combined field, laboratory, and numerical study of electromagnetic borehole flowmeter measurements acquired without the use of a packer or skirt to block bypass flow around the flowmeter. The most significant finding is that inflow through the wellbore screen changes the ratio of flow through the flowmeter to wellbore flow. Experiments reveal up to a factor of two differe...

متن کامل

A Transient Electromagnetic Flowmeter and Calibration Facility

Flowmeter and Calibration Facility P.J. Lefebvre Naval Underwater Systems Center, Newport, R.1. An electromagnetic flowmeter was developed to measure transient flows at a data rate of 60 Hz. The approach taken was to develop suitable electronics to replace the electronics ofa commercially available electromagnetic flowmeter normally used W. W. Durgin for steady-state operation. Use of the comme...

متن کامل

The Electromagnetic Flowmeter and Its Use in the Operating Room

History of Blood Flow Measurement The first attempt to measure blood flow was by Chauveau, et al. in 1869. This was a mechanical device in which the moving blood was made to strike a mechanical linkage which moved in relation to the velocity of the blood. A variety of other mechanical devices were designed to measure blood flow in the late 1800's including the Stromuhr of Carl Ludwig and the di...

متن کامل

Novel Downhole Electromagnetic Flowmeter for Oil-Water Two-Phase Flow in High-Water-Cut Oil-Producing Wells

First, the measuring principle, the weight function, and the magnetic field of the novel downhole inserted electromagnetic flowmeter (EMF) are described. Second, the basic design of the EMF is described. Third, the dynamic experiments of two EMFs in oil-water two-phase flow are carried out. The experimental errors are analyzed in detail. The experimental results show that the maximum absolute v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 1969