Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform.
نویسندگان
چکیده
Pressure wave reflection in the upper limb causes amplification of the arterial pulse so that radial systolic and pulse pressures are greater than in the ascending aorta. Wave transmission properties in the upper limbs (in contrast to the descending aorta and lower limbs) change little with age, disease, and drug therapy in adult humans. Such consistency has led to use of a generalized transfer function to synthesize the ascending aortic pressure pulse from the radial pulse. Validity of this approach was tested for estimation of aortic systolic, diastolic, pulse, and mean pressures from the radial pressure waveform. Ascending aortic and radial pressure waveforms were recorded simultaneously at cardiac surgery, before initiation of cardiopulmonary bypass, with matched, fluid-filled manometer systems in 62 patients under control conditions and during nitroglycerin infusion. Aortic pressure pulse waves, generated from the radial pulse, showed agreement with the measured aortic pulse waves with respect to systolic, diastolic, pulse, and mean pressures, with mean differences <1 mm Hg. Control differences in Bland-Altman plots for mean+/-SD in mm Hg were systolic, 0.0+/-4.4; diastolic, 0.6+/-1.7; pulse, -0.7+/-4.2; and mean pressure, -0.5+/-2.0. For nitroglycerin infusion, differences respectively were systolic, -0.2+/-4.3; diastolic, 0.6+/-1.7; pulse, -0.8+/-4.1; and mean pressure, -0.4+/-1.8. Differences were within specified limits of the Association for the Advancement of Medical Instrumentation SP10 criteria. In contrast, differences between recorded radial and aortic systolic and pulse pressures were well outside the criteria (respectively, 15.7+/-8.4 and 16.3+/-8.5 for control and 14.5+/-7.3 and 15.1+/-7.3 mm Hg for nitroglycerin). Use of a generalized transfer function to synthesize radial artery pressure waveforms can provide substantially equivalent values of aortic systolic, pulse, mean, and diastolic pressures.
منابع مشابه
Can a clinically useful aortic pressure wave be derived from a radial pressure wave?
BACKGROUND The information contained in arterial pressure waveforms is probably underused by most clinicians who manage critically ill patients. It is not generally known that an aortic pressure wave can be synthesized by applying a generalized transfer function to the radial arterial pressure wave. We validated a commercially available system, SphygmoCo (PWV Medical, Sydney). METHODS Ascendi...
متن کاملArterial functions: how to interpret the complex physiology.
Arterial pressure is a cyclic phenomenon characterized by a pressure wave oscillating around the mean blood pressure, from diastolic to systolic blood pressure, defining the pulse pressure. Aortic input impedance is a measure of the opposition of the circulation to an oscillatory flow input (stroke volume generated by heart work). Aortic input impedance integrates factors opposing LV ejection, ...
متن کاملA Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform
Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...
متن کاملGeneration of accurate aortic pressure waves from calibrated upper limb pressure waveforms.
Fourteen years ago, Chen Chen-Huan et al. from Baltimore1 were the first to validate use of a transfer function method for generation of the aortic from the radial artery pressure waveform. This technique had the potential capacity to link the century old brachial cuff sphygmomanometer with the even older clinical method of palpating or directly recording the radial arterial pressure wave. Ther...
متن کاملBlind identification of the aortic pressure waveform from multiple peripheral artery pressure waveforms.
We have developed a new technique to estimate the clinically relevant aortic pressure waveform from multiple, less invasively measured peripheral artery pressure waveforms. The technique is based on multichannel blind system identification in which two or more measured outputs (peripheral artery pressure waveforms) of a single-input, multi-output system (arterial tree) are mathematically analyz...