Testing local position invariance with four cesium-fountain primary frequency standards and four NIST hydrogen masers.

نویسندگان

  • N Ashby
  • T P Heavner
  • S R Jefferts
  • T E Parker
  • A G Radnaev
  • Y O Dudin
چکیده

We report the most sensitive tests to date of the assumption of local position invariance (LPI) underlying general relativity, based on a 7 yr comparison of cesium and hydrogen atomic clocks (frequency standards). The latest results place an upper limit that is over 20 times smaller than the previous most sensitive tests; this is consistent with the null shift predicted by LPI. The result is based on precise comparisons of frequencies of four hydrogen masers maintained by NIST, with four independent Cs fountain clocks--one at NIST and three in Europe--as the Sun's gravitational potential at Earth's surface varies due to Earth's orbital eccentricity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Second Generation Cesium Fountain Primary Frequency Standards at NIST

NIST is currently investigating the design of a second-generation cesium-fountain primary frequency standard. The design goals of this standard include an ultimate frequency inaccuracy of δf/f < 10 and achievable stability better than σy(τ) < 10/τ. This standard is expected to eventually replace NIST-F1, the current U.S. primary frequency standard [1]. In the context of reaching frequency uncer...

متن کامل

Evaluation of long term performance of continuously running atomic fountains

An ensemble of rubidium atomic fountain clocks has been put into operation at the US Naval Observatory (USNO). These fountains are used as continuous clocks in the manner of commercial caesium beams and hydrogen masers for the purpose of improved timing applications. Four fountains have been in operation for more than two years and are included in the ensemble used to generate the USNO master c...

متن کامل

Accuracy evaluation of NIST-F1

The evaluation procedure of a new laser-cooled caesium fountain primary frequency standard developed at the National Institute of Standards and Technology (NIST) is described. The new standard, NIST-F1, is described in some detail and typical operational parameters are discussed. Systematic frequency biases for which corrections are made – second-order Zeeman shift, black-body radiation shift, ...

متن کامل

Th European Frequency and Time Forum Neuchatel - 16 - 17 - 18 March 1993 Nist - 7 , the New Us Primary Frequency Standard

NIST-7, an optically pumped, cesium-beam frequency standard has replaced NBS-6 as the official US primary frequency standard. The present short-term stability of the standard, measured with respect to an active hydrogen maser, is characterized by uy(t) L 8 x i". Our first evaluation has resulted in an uncertainty of 4 x An improved servoelectronic system is being developed and this should impro...

متن کامل

Measurement of dynamic end-to-end cavity phase shifts in cesium-fountain frequency standards.

We have measured a previously unobserved systematic frequency shift in our cesium-fountain frequency standard, NIST-F1. This shift, predicted theoretically previously, mimics the well-known end-to-end phase shift in atomic beam standards when synchronous thermal transients are present. Detuning the microwave cavity several megahertz from resonance reduces this effect to the deltaf/f = 1o(-16) l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 98 7  شماره 

صفحات  -

تاریخ انتشار 2007