Performance evaluation of irreversible cascaded refrigeration and heat pump cycles

نویسندگان

  • S. C. Kaushik
  • S. Jain
چکیده

This communication presents finite time thermodynamic optimization of irreversible cascaded refrigeration and heat pump cycles having source/sink thermal reservoirs of finite heat capacitance. A general expression for the optimum coefficient of performance of the refrigerator/heat pump is derived at minimum power input and given cooling/heating load conditions, respectively. External irreversibility is due to the finite temperature difference between the system working fluids and thermal reservoirs (heat source/heat sink), while internal irreversibility is due to the non-isentropic expansion and compression within the system, which is represented by an irreversibility parameter indicating the deviation from an endoreversible case. It is found that the effect of the internal irreversibility is more pronounced as compared to the external irreversibility. The effect of various operating parameters on the cooling and heating performance of the cascaded refrigeration and heat pump cycles, respectively, is studied and numerical results are presented in the end.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Investigation of Two Two-Stage Trans-Critical Carbon Dioxide Refrigeration Cycles Ejector and Internal Heat Exchanger

In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...

متن کامل

Theoretical analysis of a novel combined cooling, heating, and power (CCHP) cycle

This study presents a theoretical analysis of a new combined cooling, heating, and power cycle by the novel integration of an organic Rankine cycle (ORC), an ejector refrigeration cycle (ERC), and a heat pump cycle (HPC) for producing cooling output, heating output, and power output simultaneously. Three different working fluids—namely R113, isobutane, and R141b—have been used in power, ref...

متن کامل

امکان‌سنجی استفاده از مبدل بازیاب حرارت در سیکل تبرید تراکمی بخار با آنالیز ترمودینامیکی، انتقال حرارت و اقتصادی

Usually, it is common to use the internal heat exchanger subcooler-superheater after the condenser and before the expansion valve in the compression refrigeration cycles. In this study, the effect of the heat exchanger is evaluated by using recovery heat exchanger after the compressor and before the condenser. To this end, the vapor compression refrigeration cycle with conventional heat exchang...

متن کامل

Thermal Design Considerations and Performance Evaluation of Cryogenic Tube in Tube Heat Exchangers

Heat exchangers are the most important equipment in refrigeration processes. Design and modeling of heat exchangers operating at low temperatures are different from other regular heat exchangers. This study includes two sections. In the first section, design and modeling considerations needed for evaluating the real thermal behavior of heat exchangers at low temperatures were discussed. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005