CLINICAL SCIENCE Evaluation of the validity and reliability of A-scan ultrasound biometry with a single use disposable cover

نویسندگان

  • K Cass
  • C M Thompson
  • C Tromans
  • I C J Wood
چکیده

Background: The UK Medical Devices Agency has suggested that ophthalmic practitioners should, where practicable and not compromising clinical outcome, restrict corneal contact devices to single patient use to minimise a remote theoretical risk of transmission of new variant Creutzfeldt-Jakob disease (vCJD). This study reports on a modified technique of ultrasound A-scan biometry that complies with the MDA recommendations. Methods: The right eyes of 37 consecutive hospital patients had a series of biometry readings taken with a Humphrey 820 A-scan instrument with a plane wave transducer use d conventionally and with the addition of a disposable latex cover. Results: Intrasessional repeatability of axial length measurements was similar for conventional readings—mean difference 0.027 mm, 95% confidence intervals (CI) ± 0.44 mm and those taken with a disposable cover (0.028 mm, CI ± 0.38). Intersessional repeatability was equivalent with (0.002 mm, CI ± 0.51) and without a cover (0.03 mm, CI ± 0.51). Readings with a cover were not significantly different from those without (paired t test; p >0.05), but tended to be greater (mean difference 0.085 mm, CI ± 0.60). Conclusions: These findings suggest that corneal contact biometry with a disposable cover is a viable and theoretically safer alternative to the conventional technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the validity and reliability of A-scan ultrasound biometry with a single use disposable cover.

BACKGROUND The UK Medical Devices Agency has suggested that ophthalmic practitioners should, where practicable and not compromising clinical outcome, restrict corneal contact devices to single patient use to minimise a remote theoretical risk of transmission of new variant Creutzfeldt-Jakob disease (vCJD). This study reports on a modified technique of ultrasound A-scan biometry that complies wi...

متن کامل

A Review of New Methods Assessment in Clinical Education of Medical Science Students

Introduction: Clinical education is an important part of education in medical sciences. One of the most important barriers to clinical education is the problems with the evaluation system. Studies with controversial results have been conducted in the field of clinical evaluation methods. The purpose of this study was to systematically review the research done to determine the appropriate clinic...

متن کامل

The validity and reliability of the Brief Fear of Negative Evaluation Scale in women with tension-type headaches

Aim and Background: Examining fear of negative evaluation as one of psychological causes in headaches is important. The aim of the present study was to investigate validation and psychometric properties of the Brief Fear of Negative Evaluation Scale (BFNES, Leary, 1983) in a group of women with tension-type headaches. Methods and Materials: A total of 110 women with tension-type headaches in ...

متن کامل

Somatic Symptom Scale -8 in Major Depressive Disorder: A Psychometric Evaluation

Objective: Somatic symptom disorder (SSD) is characterized by somatic symptoms that are very distressing or cause considerable functional disability. SSD is associated with various medical and psychiatric conditions and imposes high costs on the patient's health care system. Therefore, diagnosis and treatment of SSD are crucial. The Somatic Symptom Scale-8 (SSS-8) is a valuable and brief self-r...

متن کامل

Clinical Evaluation Tool for Operating Room Students: Development and Measurement of Reliability and Validity

Introduction: In order to ensure the achievement of goals in clinical training, having the right tool with good reliability and validity is essential. Given the fact that no proper tool has ever been developed for evaluation of operating room students, this study aimed to develop and measure the validity and reliability of the evaluation tool for these students. Methods: This descriptive study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002