Novel 16-channel receive coil array for accelerated upper airway MRI at 3 Tesla.
نویسندگان
چکیده
Upper airway MRI can provide a noninvasive assessment of speech and swallowing disorders and sleep apnea. Recent work has demonstrated the value of high-resolution three-dimensional imaging and dynamic two-dimensional imaging and the importance of further improvements in spatio-temporal resolution. The purpose of the study was to describe a novel 16-channel 3 Tesla receive coil that is highly sensitive to the human upper airway and investigate the performance of accelerated upper airway MRI with the coil. In three-dimensional imaging of the upper airway during static posture, 6-fold acceleration is demonstrated using parallel imaging, potentially leading to capturing a whole three-dimensional vocal tract with 1.25 mm isotropic resolution within 9 sec of sustained sound production. Midsagittal spiral parallel imaging of vocal tract dynamics during natural speech production is demonstrated with 2 × 2 mm(2) in-plane spatial and 84 ms temporal resolution.
منابع مشابه
A Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T
PURPOSE To design, construct and validate radiofrequency (RF) transmit and receive phased array coils for high-resolution visual cortex imaging at 7 Tesla. METHODS A 4 channel transmit and 16 channel receive array was constructed on a conformal polycarbonate former. Transmit field efficiency and homogeneity were simulated and validated, along with the Specific Absorption Rate, using [Formula:...
متن کاملMultiple-Animal MR Imaging Performed using a 3-Tesla Whole-body Scanner: A Feasibility Study using a 16-Channel Array Coil
before (left) and after (right) signal intensity correction. The images of the other 2 rats were simultaneously obtained and were of comparable quality (not shown). Fig.1. Sixteen-channel coil dedicated for small animal MRI. An array comprises 8 5-cm-circular coils (a). The 16-channel coil has 2 sets of 8-array coils in the upper and lower parts (b). A white bar on the top is used to adjust the...
متن کاملParallel imaging of the upper airway with a novel 16-channel tongue coil
Introduction: Recently, Hayes et al. proposed novel designs for 12and 16-channel tongue coil arrays and demonstrated their ability to improve tongue SNR [1]. The coil array provides highly localized sensitivity that includes the tongue and upper airway. In this work, we measure and analyze the SNR and g-factor of the 16-channel tongue coil for several tissues of interest, in a mid-sagittal scan...
متن کامل96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation.
The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive-only phased-array head coil with 96 receive elements constructed on a close-fitting helmet-shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal-to-noise ratio (SNR) loss, includin...
متن کاملA 16-Channel Receive, Forced Current Excitation Dual-Transmit Coil for Breast Imaging at 7T
PURPOSE To enable high spatial and temporal breast imaging resolution via combined use of high field MRI, array coils, and forced current excitation (FCE) multi channel transmit. MATERIALS AND METHODS A unilateral 16-channel receive array insert was designed for use in a transmit volume coil optimized for quadrature operation with dual-transmit RF shimming at 7 T. Signal-to-noise ratio (SNR) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 65 6 شماره
صفحات -
تاریخ انتشار 2011