Long-term reproducibility of microvolt T-wave alternans in patients after cardioverter-defibrillator implantation.

نویسندگان

  • Robert Wierzbowski
  • Dariusz Michałkiewicz
  • Karol Makowski
  • Paweł Smurzyński
  • Robert Ryczek
  • Andrzej Cwetsch
  • Marian Cholewa
چکیده

BACKGROUND Microvolt T-wave alternans (MTWA) is a promising method for noninvasive assessment of arrhythmic risk. Recent studies have shown good immediate reproducibility of T-wave alternans. Little is known about it during the long term. The aim of the study was to prospectively evaluate the long-term reproducibility of MTWA in a group of patients after ICD implantation. METHODS The study group consisted of 22 patients: 21 male and 1 female, aged 63.0 +/- 7.6 years. Nineteen of them had a history of myocardial infarction and 3 had non-ischemic cardiomyopathy. Ejection fraction was 34.7 +/- 10.0. T-wave alternans was measured during treadmill tests and additionally in 6 patients during implantation cardioverter-defibrillator device pacing. We received 30 reports of MTWA available for analysis. The second test was performed after 11.8 +/- 3.3 months (range 7-16) using the same protocol. RESULTS Of the 30 tests, 12 were positive, 2 negative and 9 indeterminate in both tests. The results were concordant in 23 tests (76.66%) (Kappa 0.602). Of the initial positive tests, only one became negative in the second test and 4 became indeterminate. Of the initial negative tests, none became positive and none became indeterminate. Of the initial indeterminate tests, one became positive and one negative. At the same time, there were no significant differences between QRS, QTc and ejection fraction between the first and second tests. Only the heart rate in the second test was greater than in the first. CONCLUSIONS The results suggest that microvolt T-wave alternans measurement is stable over a long period. It is probably not worth examining the status of MTWA after several months, at least if patients are in the chronic stage of their disease. (Cardiol J 2007; 14: 561-567).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiple autonomic and repolarization investigation of sudden cardiac death in dilated cardiomyopathy and controls.

BACKGROUND Prophylactic defibrillator implantation is recommended in dilated, nonischemic heart disease and left ventricular ejection fraction of ≤0.30 to 0.35. Noninvasive testing should improve accuracy in decision making of prophylactic defibrillator implantation. METHODS AND RESULTS We enrolled 60 patients (median age, 57 years) with dilated cardiomyopathy and left ventricular ejection fr...

متن کامل

Immediate ventricular tachycardia after abnormal microvolt T-wave alternans.

Microvolt T-wave alternans (MTWA) is a promising non-invasive method of evaluating repolarization abnormalities. Its presence is strongly related to the occurrence of malignant ventricular tachyarrhythmias and is therefore regarded as a risk marker for sudden cardiac death. Most recent studies have described the usefulness of MTWA in selecting patients who may benefit from a cardioverter-defibr...

متن کامل

Prospective Use of Microvolt T-Wave Alternans Testing to Guide Primary Prevention Implantable Cardioverter Defibrillator Therapy.

BACKGROUND We hypothesized that a negative microvolt T-wave alternans (MTWA) test would identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillator (ICD) therapy in a prospective cohort. METHODSANDRESULTS Data were pooled from 8 centers where MTWA testing was performed specifically for the purpose of guiding primary prevention ICD implantation. Cohorts...

متن کامل

Application of microvolt T-wave alternans testing in scheduling implantable cardioverter-defibrillator placement for the primary prevention of sudden cardiac death in patients with left ventricular dysfunction.

BACKGROUND Patients with left ventricular ejection fraction (LVEF) ≤ 35% are eligible for implantable cardioverter-defibrillator (ICD) placement for the primary prevention of sudden cardiac death (SCD). This recommendation results in continuously growing waiting lists of patients who have been qualified for and are awaiting the procedure. Whiled reduced LVEF is a feature shared by all the patie...

متن کامل

The problem of indeterminate microvolt T-wave alternans results in patients with left ventricular dysfunction referred for implantable cardioverter-defibrillator implantation in the primary prevention of sudden cardiac death.

BACKGROUND Microvolt T-wave alternans (MTWA) is a recommended noninvasive diagnostic test for predicting the risk of sudden cardiac death (SCD). However, about 6% to 41% of MTWA results are indeterminate. The causes, interpretation and clinical significance of these results have not been not clearly established. AIM To assess frequency, causes, and prognostic significance of indeterminate MTW...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cardiology journal

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2007