Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound

نویسندگان

  • Adriano Caixeta
  • Vanessa Cristina Salomon Palma Braga
  • Gary S Mintz
چکیده

A 60-year-old man with a history of implantation of two bare-metal stents 2 years prior presented to the emergency department with new-onset chest pain. He has been regularly taking angiotensinconverting enzyme inhibitors, beta blockers and aspirin. Aspirin was suspended for 10 days prior to the current hospitalization in order to perform surgery to remove a kidney tumor. He underwent coronary angiography, which revealed a right coronary artery with a distal intraluminal defect within the stents, suggesting thrombus. Intravascular ultrasound demonstrated a severe malapposition and underexpansion throughout the entire length of the stents containing thrombus. In this case, the mechanisms of very late stent thrombosis after bare-metal stent most likely were a combination of mechanical factors (severe stent undersizing during the index procedure) and pharmacological factors (aspirin discontinuation).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravascular ultrasound and histology findings in very late bare-metal stent thrombosis.

Very late thrombosis in an implanted bare-metal stent is a very uncommon event outside the context of brachytherapy and few data about its pathophysiology are available. We performed an intravascular ultrasound study during primary angioplasty in five patients with very late bare-metal stent thrombosis and carried out a histological analysis of the material removed by manual thrombectomy. The m...

متن کامل

Heterogeneous Intravascular Ultrasound Findings of Stent Thrombosis

Objective The underlying mechanisms of stent thrombosis are not completely understood. Methods We experienced 12 definite stent thrombosis cases (1 early, 1 late, and 10 very late) at our hospital from July 2011 to April 2016 and evaluated the possible causes of stent thrombosis by intravascular ultrasound (IVUS). Results Five different potential morphological causes of stent thrombosis (neoath...

متن کامل

IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled

The use of intravascular ultrasound (IVUS) to improve acute angiographic results was already shown in the prestent era. Various studies demonstrated the efficacy of IVUS in balloon sizing and estimating the extent of positive remodeling. With the introduction of drug-eluting stents (DES) the rate of restenosis has been significantly reduced but a new concern, the risk of stent thrombosis, has e...

متن کامل

Background incidence of late malapposition after bare-metal stent implantation.

BACKGROUND Late stent malapposition has been reported to be an abnormal finding after vascular brachytherapy and, possibly, implantation of drug-eluting stents. It can only be detected if intravascular ultrasound (IVUS) is performed at follow-up. However, the "background" frequency of late stent malapposition after bare-metal stent implantation is not known. METHODS AND RESULTS We studied 206...

متن کامل

Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.

BACKGROUND Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2013