Pulmonary Vein Isolation by High Intensity Focused Ultrasound
نویسندگان
چکیده
Pulmonary vein isolation (PVI) using radiofrequency current (RFC) ablation is a potentially curative treatment option for patients with atrial fibrillation (AF). The shortcomings of the RFC technology (technically challenging, long procedure times, complications) steadily kindle the interest in new energy sources and catheter designs. High intensity focused ultrasound (HIFU) has the ability to precisely focus ultrasound waves in a defined area with a high energy density. HIFU balloon catheters (BC) positioned at the PV ostia appear to be an ideal tool to transmit the ablation energy in a circumferential manner to the PV ostia and may therefore bear substantial advantage over conventional ablation catheters in PVI procedures. In clinical trials the HIFU BC has shown promising success rates similar to RFC catheter ablation for PVI in patients with AF. However, procedure times are still long and serious complications have been observed. Therefore, it may be a valuable alternative to the conventional techniques in selected patients but further clinical trials have to be initiated.
منابع مشابه
Long-term clinical outcome following pulmonary vein isolation with high-intensity focused ultrasound balloon catheters in patients with paroxysmal atrial fibrillation.
AIMS High-intensity focused ultrasound (HIFU) applied via a balloon catheter is a novel technology for pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF). The long-term success rate is unknown. METHODS AND RESULTS Thirty-two patients (22 male, age 60 +/- 9 years) with a long history [5 (4;9) years] of drug refractory [3 +/- 1 anti-arrhythmic drugs (AADs)], sy...
متن کاملFatal end of a safety algorithm for pulmonary vein isolation with use of high-intensity focused ultrasound.
BACKGROUND High-intensity focused ultrasound (HIFU) can achieve pulmonary vein isolation (PVI), but there are safety concerns after severe complications. Therefore, we evaluated an esophageal temperature (ET)-guided safety algorithm to apply HIFU safely. METHODS AND RESULTS After standard left atrial access, HIFU was repeatedly applied until PVI was complete. A safety algorithm was used: <or=...
متن کاملCapacitive Micromachined Ultrasonic Transducer Arrays for Integrated Diagnostic/Therapeutic Catheters
In recent years, medical procedures have become increasingly non-invasive. These include endoscopic procedures and intracardiac interventions (e.g., pulmonary vein isolation for treatment of atrial fibrillation and plaque ablation for treatment of arteriosclerosis). However, current tools suffer from poor visualization and difficult coordination of multiple therapeutic and imaging devices. Dual...
متن کاملMicrosoft Word - 922930_final ms for production.docx
Background: High-intensity focused ultrasound (HIFU) can achieve pulmonary vein isolation (PVI), but there are safety concerns after severe complications. Therefore we evaluated an esophageal temperature (ET) guided safety algorithm in order to apply HIFU safely. Methods and Results: After standard left atrial access HIFU was repeatedly applied until complete PVI. Safety algorithm: 3 complete a...
متن کاملElectrophysiological efficacy of Epicor high-intensity focused ultrasound.
OBJECTIVES Clinical success of atrial fibrillation (AF) ablation depends on persistent blocking of electrical conduction across the ablation lines. Epicor high-intensity focused ultrasound (HIFU) ablation has been credited with a variable clinical efficacy. The aim of this work is to ascertain the electrophysiological (EP) efficacy of such lesions, by assessing pulmonary vein isolation (PVI) af...