SLEEP DISORDERED BREATHING Operating characteristics of the negative expiratory pressure technique in predicting obstructive sleep apnoea syndrome in snoring patients
نویسندگان
چکیده
Background: This study examines the operating characteristics of the expiratory flow response to a negative pressure (NEP) applied to the mouth in the prediction of obstructive sleep apnoea syndrome (OSAS) in snoring patients. Methods: Two hundred and thirty eight patients with normal spirometric values were studied. Full laboratory polysomnography was performed and an NEP of 25 cm H2O was applied in the sitting and supine positions. Results: A significant correlation was found between the degree of flow limitation measured by NEP in both positions (expressed as the percentage of the expired tidal volume over which NEP induced flow did not exceed spontaneous flow) and the apnoea-hypopnoea index (AHI). This correlation was significantly higher in the supine position (p,0.0001) where an expiratory flow limitation cut off value of >27.5% of the tidal volume produced a sensitivity of 81.9% and a specificity of 69.1% in predicting OSAS. Conclusion: These findings show that the degree of instability of the upper airway measured by NEP is correlated with the severity of OSAS. NEP had moderate sensitivity and specificity and may be useful in predicting OSAS in a clinic based population.
منابع مشابه
Operating characteristics of the negative expiratory pressure technique in predicting obstructive sleep apnoea syndrome in snoring patients.
BACKGROUND This study examines the operating characteristics of the expiratory flow response to a negative pressure (NEP) applied to the mouth in the prediction of obstructive sleep apnoea syndrome (OSAS) in snoring patients. METHODS Two hundred and thirty eight patients with normal spirometric values were studied. Full laboratory polysomnography was performed and an NEP of -5 cm H(2)O was ap...
متن کاملSleep disordered breathing.
A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea. advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Assessment of upper airway dynamics in awake sleep apnea patients wi...
متن کاملSleep-disordered breathing.
A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea. advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Assessment of upper airway dynamics in awake sleep apnea patients wi...
متن کاملEvaluation of an auto-nCPAP device based on snoring detection.
We evaluated an auto-nasal continuous positive airway pressure (nCPAP) prototype (MC+; SEFAM, Nancy, France) in which apnoea/hypopnoea detection was disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The device was tested in 15 previously untreated obstructive sleep apnoea patients during a night with polysomnography. We observed that a single night of a...
متن کاملIdentification of sleep disruption and sleep disordered breathing from the systolic blood pressure profile.
BACKGROUND Respiratory sleep studies are frequently performed to identify sleep disruption resulting from upper airway obstruction. Traditional polysomnographic studies may not detect brief recurrent sleep disruption and thus fail to recognise a significant problem when apnoea, hypopnoea, or arterial desaturation are not present. Arousal from sleep causes a transient blood pressure rise, and ea...