Human biological pacemakers: intrinsic variability and stability.

نویسندگان

  • Crystal M Ripplinger
  • Donald M Bers
چکیده

Human Biological Pacemakers: Intrinsic Variability and Stability Print ISSN: 0009-7322. Online ISSN: 1524-4539 Copyright © 2012 American Heart Association, Inc. All rights reserved. is published by the American Heart Association, 7272 Greenville Avenue, Dallas, TX 75231 Circulation doi: 10.1161/CIRCULATIONAHA.111.086827 2012;125:856-858; originally published online January 18, 2012; Circulation. http://circ.ahajournals.org/content/125/7/856 World Wide Web at: The online version of this article, along with updated information and services, is located on the

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human embryonic and induced pluripotent stem cell-derived cardiomyocytes exhibit beat rate variability and power-law behavior.

BACKGROUND The sinoatrial node is the main impulse-generating tissue in the heart. Atrioventricular conduction block and arrhythmias caused by sinoatrial node dysfunction are clinically important and generally treated with electronic pacemakers. Although an excellent solution, electronic pacemakers incorporate limitations that have stimulated research on biological pacing. To assess the suitabi...

متن کامل

Feedback control of variability in the cycle period of a central pattern generator.

We address how feedback to a bursting biological pacemaker with intrinsic variability in cycle length can affect that variability. Specifically, we examine a hybrid circuit constructed of an isolated crab anterior burster (AB)/pyloric dilator (PD) pyloric pacemaker receiving virtual feedback via dynamic clamp. This virtual feedback generates artificial synaptic input to PD with timing determine...

متن کامل

Sliding Mode Control For Heartbeat Electrocardiogram Tracking Problem

In this paper, we have exploited the first-order sliding mode control method to track the ECG data of the human heart by three different nonlinear control laws. In order to lessen the intrinsic chattering of the classic sliding mode control system, smooth function approximations of the control input, by means of the hyperbolic tangent and the saturation function, were used. The fast Fourier tra...

متن کامل

A model of cardiac tissue as a conductive system with interacting pacemakers and refractory time

A model of the heart tissue as a conductive system with two interacting pacemakers and a refractory time, is proposed. In the parametric space of the model the phase locking areas are investigated in detail. Obtained results allow us to predict the behaviour of excitable systems with two pacemakers depending on the type and intensity of their interaction and the initial phase. Comparison of the...

متن کامل

Within-Session Stability of Short-Term Heart Rate Variability Measurement

The primary aim of this study was to assess the retest stability of the short-term heart rate variability (HRV) measurement performed within one session and without the use of any intervention. Additionally, a precise investigation of the possible impact of intrinsic biological variation on HRV reliability was also performed. First, a single test-retest HRV measurement was conducted with 20-30 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 125 7  شماره 

صفحات  -

تاریخ انتشار 2012