Fluorimetric determination of total ascorbic acid by a stopped-flow mixing technique.

نویسندگان

  • T Pérez-Ruiz
  • C Martínez-Lozano
  • V Tomás
  • J Fenoll
چکیده

A simple, rapid and automatic fluorimetric method for the determination of total ascorbic acid is described. The method makes use of the stopped-flow mixing technique in order to achieve the rapid oxidation of ascorbic acid by dissolved oxygen to dehydroascorbic acid, which then reacts with o-phenylenediamine to form a fluorescent quinoxaline. The initial rate and fluorescence signal of this system are directly proportional to the ascorbic acid concentration. The calibration graph was linear over the range 0.1-30 microg ml(-1) (kinetic method) and 0.25-34 microg ml(-1) (equilibrium method). The precision (% RSD) was close to 0.5%. The method has been used for the determination of ascorbic acid in pharmaceutical formulations, fruit juices, soft drinks and blood serum.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

Semi-automated method for the differential determination of plasma catecholamines.

A method is described for the estimation of adrenaline and noradrenaline in a 5 to 10 ml plasma sample.A batch technique of adsorption and elution from alumina is used and the final estimation is carried out using an automated fluorimetric technique based on the trihydroxyindole method. Fluorescence is stabilized first by thioglycollic acid to give noradrenaline concentrations only and then by ...

متن کامل

Nonenzymatic stopped-flow fluorimetric method for direct determination of uric acid in serum and urine.

A simple, direct, sensitive, and selective stopped-flow method for the fluorimetric determination of uric acid in serum and urine samples is described. The variation of fluorescence intensity during the reaction between uric acid and 1,1,3-tricyano-2-amino-1-propene (triap) in the presence of hydrogen peroxide is monitored. For these kinetic measurements peroxide is monitored. For these kinetic...

متن کامل

Platinum Nanoparticle Electrode Modified Iodine using Cyclic Voltammetry and Chronoamperometry for Determination of Ascorbic Acid

This study investigated the oxidation of ascorbic acid (Vitamin C) using a platinum nanoparticle electrode coated with an iodine monolayer, called a modified electrode. The electrode were grown using the cyclic voltammetry technique and the electrochemical measurements were taken using the cyclic voltammetry and chronoamperometric technique. In the case of platinum nanoparticle electrode modifi...

متن کامل

Determination of proteins in serum by fluorescence quenching of rose bengal using the stopped-flow mixing technique.

The stopped-flow mixing technique was used to develop a very fast, sensitive and accurate method for determining total proteins. The method is based on the lower fluorescence of Rose Bengal caused by binding of the dye to the proteins. The decrease in the fluorescence intensity, measured at 572 nm with excitation 555 nm, was linearly related to protein concentration from 1.3 to 24.5 micrograms ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 126 8  شماره 

صفحات  -

تاریخ انتشار 2001