Quantitative investigation of cardiac motion effects on in vivo diffusion tensor parameters: a simulation study
نویسندگان
چکیده
Background Cardiac motion is a crucial problem in in vivo diffusion tensor imaging (DTI) of the human heart. Despite its importance, the effects of cardiac motion on diffusion tensor parameters of the human heart in vivo have not been well established, mainly because of large signal loss. Recently, an efficient method was proposed that acquires cardiac diffusion weighted (DW) images at different time points of the cardiac cycle and reduces motion-induced signal loss using PCA filtering and temporal MIP techniques (PCATMIP) (Rapacchi, Invest Radiol 2011). Meanwhile, polarized light imaging (PLI) provides us the ground-truth of the heart fiber architecture, and DENSE sequence offers us higher spatial resolution displacement fields of the human heart in vivo. These different imaging possibilities have led us to investigate a multimodal approach to quantitatively investigate the effects of cardiac motion on diffusion tensor parameters such as
منابع مشابه
Second order motion compensated spin-echo diffusion tensor imaging of the human heart
PURPOSE Myocardial microstructure has been challenging to probe in vivo. Spin echo-based diffusion-weighted sequences allow for single-shot acquisitions but are highly sensitive to cardiac motion. In this study, the use of second-order motion-compensated diffusion encoding was compared with first-order motion-compensated diffusion-weighted imaging during systolic contraction of the heart. MET...
متن کاملAnalysis and Design of Higher-Order Motion-Compensated Diffusion Encoding Schemes for In Vivo Cardiac DTI
Introduction: Cardiac diffusion tensor imaging (DTI) [1-3] is increasingly used to characterize myocardial microstructure and myofiber orientation in both normal and diseased hearts. Clinical applications of the technique in humans have been made feasible by employing either STEAM [4] or bipolar diffusion encoding [5] in conjunction with acquisition during the quiescent phase of the cardiac cyc...
متن کاملEx vivo cardiac DTI: on the effects of diffusion time and b-value
Background For in-vivo an ex-vivo studies of myocardial structure, generally a spin echo (SE) or stimulated echo (STE) based sequence is used. Diffusion weighting is reported with a large range of diffusion times (50 and 1000 ms). Furthermore, in-vivo studies generally use low b-values (300 s/mm) whereas ex-vivo experiments allow for much higher b-values. For interpretation of in-vivo cardiac D...
متن کاملSecond order motion compensated spin echo cardiac diffusion tensor imaging on clinical MR systems
Background Recently second order motion compensated spin echo (SE) sequences in conjunction with high performance gradient systems have been proposed for diffusion weighted (DWI) [1] and diffusion tensor imaging (DTI) [2,3] of the human in vivo heart. The method allows for free breathing acquisition without requiring dedicated patient feedback systems or other provisions [4], facilitating the t...
متن کاملCardiac diffusion MRI without motion effects.
We present a method for diffusion tensor MRI in the beating heart that is insensitive to cardiac motion and strain. Using a stimulated echo pulse sequence with two electrocardiogram (ECG) triggers, diffusion-encoding bipolar gradient pulses are applied at identical phases in consecutive cardiac cycles. In this experiment, diffusion is encoded at a single phase in the cardiac cycle of less than ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2013