Reproducibility of cardiac output measurement by cross sectional and Doppler echocardiography.

نویسندگان

  • S C Robson
  • A Murray
  • I Peart
  • A Heads
  • S Hunter
چکیده

The variability of Doppler echocardiographic estimation of cardiac output at the aortic orifice was investigated in eight healthy subjects. Cross sectional echocardiograms of the aortic orifice and aortic Doppler velocities were recorded and measured by four echocardiographers. Between subject variability was significantly larger than within subject variability for all variables. Variability owing to different echocardiographers and different measurement times was small compared with total variability. Coefficients of variation for aortic annular diameter, aortic velocity integral, and heart rate were 4.1%, 6.4%, and 5.0% respectively. The coefficient of variation for cardiac output was 8.8% and the 95% confidence interval for measurement of cardiac output by the Doppler method was 4.45 to 6.35 l/min. One echocardiographer reanalysed all the recordings and the results showed that recording the echocardiograms introduces a significantly larger source of error than measuring them. Thus serial measurements of cardiac output by the Doppler method can be performed with acceptable reproducibility; this indicates that the technique can be accurately applied in clinical practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler echocardiographic measurement of aortic valve area in aortic stenosis: a noninvasive application of the Gorlin formula.

Thirty adult patients with aortic stenosis had Doppler echocardiography within 1 day of cardiac catheterization. Noninvasive measurement of the mean transaortic pressure gradient was calculated by applying the simplified Bernoulli equation to the continuous wave Doppler transaortic velocity recording. Stroke volume was measured noninvasively by multiplying the systolic velocity integral of flow...

متن کامل

Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.

Interobserver reproducibility in deriving cardiac output by measuring aortic blood flow velocity and diameter with imaging and Doppler ultrasound was investigated in 20 healthy infants born at full term. Aortic diameter was measured in three ways. Mean blood flow velocity was measured at three sites with both continuous wave and pulsed Doppler. Two observers carried out each study independently...

متن کامل

Cardiac Involvement in Mild Cystic Fibrosis Lung Involvement Assessed by Tissue‐Doppler Echocardiography

Background:Cystic Fibrosis (CF) is a systemic disease affecting extra pulmonary dysfunction as a result of CF-related lung disease. Because of lack of enough studies in this field and utilization of TDE in this field, we aimed to evaluate t...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Doppler echocardiographic measurement of cardiac output using the mitral orifice method.

Cardiac output was determined in 20 patients with various cardiac conditions by measuring the cross sectional area of the mitral orifice by echocardiography and the transmitral flow by the Doppler technique. Cardiac output was calculated by multiplying the corrected mitral orifice area by the maximum diastolic velocity integral recorded by the pulsed mode. The results were compared with that ob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 59 6  شماره 

صفحات  -

تاریخ انتشار 1988