A fetal electrocardiographic electrode.

نویسنده

  • E. H. Hon
چکیده

A FETAL ELECTROCARDIOGRAPHIC ELECTRODEt Although it is sixty years since the first fetal electrocardiogram (FECG) was recorded by Cremer,1 it is only in recent years that attempts have been made to improve the FECG signal-to-noise ratio so that FECG configuration changes can be evaluated and the FECG used as a reliable trigger for automatic fetal heart rate (FHR) counting circuits. While the FECG signal-to-noise ratio can be improved by group averaging a number of consecutive FECG complexes with a digital computer,"' the most direct method is to attach an electrode directly to the fetus by either the trans-abdominal or transcervical routes." Unfortunately, the difficulties and hazards of these procedures limit their use to research. Some seven years ago, an electrode was made from a wound clip, insulated, and attached to the fetal presenting part.' This was applied after rupture of the membranes, with the cervix at least 2 cm. dilated and the presenting part no higher than a-2 station. With this electrode, it has been possible to accumulate a sizeable body of research and clinical data on the FECG and FHR patterns that was previously not available. Currently , the construction of the electrode is being revised with newer insulating materials. While the statistical evaluation of the revised FECG electrode is not yet complete, the marked improvement in FECG signal-to-noise ratio obtained with these electrodes has so improved FHR monitoring techniques that they will be described at this time. Our earlier FECG electrodes usually provided signals of 50 to 75 microvolts in amplitude. With the revised electrode, FECG's are usually in the range of 300 to 500 microvolts and signals as high as 800 microvolts have been recorded. As a result, there is a pronounced improvement in the FECG signal-to-noise ratio so that the details of the FECG baseline can be identified clearly and an almost artefact-free plot of FHR obtained throughout labor and delivery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the effects of the continuous electrode paste band on precordial leads of the electrocardiogram.

OBJECTIVE - To determine if the application of a continuous electrode paste band on precordial leads results in alteration of the electrocardiographic tracing as compared with an adequate amount of electrode paste, and if the former condition does not cause uniform morphologies from V1 to V6. METHODS - The amplitude and morphology of the electrocardiographic waves on the precordial leads in ele...

متن کامل

Electrocardiogram in rabbit fetuses.

• Although indirect fetal electrocardiograph}' in human pregnancies is becoming common,' electrocardiograms of mammalian fetuses in utero by the direct approach are not. During a general electrophysiological study of rabbit fetuses, we found that electrocardiograms could be obtained easily with needle electrodes. We expanded our observations by making recordings of cardiac potentials via needle...

متن کامل

Postural electrocardiographic changes in healed myocardial infarction.

An electrocardiographic study of 110 patients with old myocardial infaretion was made. Chan.Ige of posture, by causing rotation of the heart on its axes, frequently altered the evidence of infarction. These changes were most evident in posterior infarction. The "labele(l" area (lid the following with respect to the exploring electrode: (1) disappeared, (2) if absent in the supine posture, the e...

متن کامل

Postural Electrocardiographic Changes in Healed Myocardial Infarction By BERNARD

An electrocardiographic study of 110 patients with old myocardial infaretion was made. Chan.Ige of posture, by causing rotation of the heart on its axes, frequently altered the evidence of infarction. These changes were most evident in posterior infarction. The "labele(l" area (lid the following with respect to the exploring electrode: (1) disappeared, (2) if absent in the supine posture, the e...

متن کامل

Fetal Arrhythmias: A Clinical Review

Fetal rhythm abnormalities occur in 2% of pregnancies. They are usually identified by the obstetrician or midwifes after 20 weeks. There are four different methods used to assess fetal arrhythmias: scalp electrodes attached to electrocardiographic recordings, magnetocardiography (FMCG), fetal electrocardiographic recordings from the maternal abdomen, and fetal echocardiography (M-mode, pulsed-D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Yale Journal of Biology and Medicine

دوره 39  شماره 

صفحات  -

تاریخ انتشار 1966