Multiplex LightCycler PCR assay for detection and differentiation of Bordetella pertussis and Bordetella parapertussis in nasopharyngeal specimens.

نویسندگان

  • Lynne M Sloan
  • Marlene K Hopkins
  • P Shawn Mitchell
  • Emily A Vetter
  • Jon E Rosenblatt
  • W Scott Harmsen
  • Franklin R Cockerill
  • Robin Patel
چکیده

A rapid real-time multiplex PCR assay for detecting and differentiating Bordetella pertussis and Bordetella parapertussis in nasopharyngeal swabs was developed. This assay (LC-PCR-IS) targets the insertion sequences IS481 and IS1001 of B. pertussis and B. parapertussis, respectively, and is performed using the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.). The analytical sensitivity is less than one organism per reaction. Results for Bordetella culture and/or direct fluorescent antibody testing and a second LightCycler PCR assay (target, pertussis toxin gene) were compared to results of the LC-PCR-IS assay for 111 nasopharyngeal swabs submitted for pertussis testing. Of the specimens, 12 were positive (9 B. pertussis and 3 B. parapertussis) and 68 specimens were negative by all methods. Three other specimens were positive for B. pertussis by at least two of the methods (including the LC-PCR-IS assay), and another 28 specimens were positive for B. pertussis by the LC-PCR-IS assay only. No specimens were negative by the LC-PCR-IS assay and positive by the other methods. A conventional PCR method (target, IS481) was also compared to the LC-PCR-IS assay for a different group of nasopharyngeal swab specimens (n = 96): 44 specimens were positive and 41 specimens were negative for B. pertussis with both PCR methods. Nine specimens were positive for B. pertussis by the LC-PCR-IS assay and negative by the conventional PCR assay, and two specimens were positive for B. pertussis by the conventional PCR assay and negative by the LC-PCR-IS assay. Positivity of the two assays was not significantly different (P = 0.0654). The insertion sequence IS481 is also present in Bordetella holmesii; specimens containing B. holmesii may yield false-positive results. The LC-PCR-IS assay takes approximately 45 min to complete post-nucleic acid extraction, compared to 24 h for the conventional PCR assay previously used in our laboratory. The LC-PCR-IS assay is easier to perform than the conventional PCR assay, and the closed system decreases the chance of contamination. All of these characteristics represent a significant improvement in the detection of B. pertussis and B. parapertussis in nasopharyngeal specimens.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiplex real-time PCR assay for detection and differentiation of Bordetella pertussis and Bordetella parapertussis

A triplex real-time PCR assay for detection and differentiation of Bordetella pertussis and Bordetella parapertussis was developed. Three targets were used for amplification in a single tube: the insertion sequence IS481 and the pertussis toxin promoter region (ptxP) for B. pertussis, and the insertion sequence IS1001 for B. parapertussis. The performance of this PCR assay was evaluated in para...

متن کامل

Real-time LightCycler PCR for detection and discrimination of Bordetella pertussis and Bordetella parapertussis.

Real-time PCR assays based on the LightCycler technology were developed for individual (simplex PCR) and simultaneous (duplex PCR) detection and discrimination of Bordetella pertussis and Bordetella parapertussis in clinical samples. The assays were evaluated with 113 specimens from patients with and without symptoms of pertussis. Results were compared to those from conventional culture and Taq...

متن کامل

Novel multitarget real-time PCR assay for rapid detection of Bordetella species in clinical specimens.

A novel multitarget real-time PCR (RT-PCR) assay for the rapid identification of Bordetella pertussis, B. parapertussis, and B. holmesii was developed using multicopy insertion sequences (ISs) in combination with the pertussis toxin subunit S1 (ptxS1) singleplex assay. The RT-PCR targets for the multiplex assay include IS481, commonly found in B. pertussis and B. holmesii; IS1001 of B. parapert...

متن کامل

Evaluation of PCR for diagnosis of Bordetella pertussis and Bordetella parapertussis infections.

PCR, using primers Plp1 and Plp2, was evaluated for the detection of DNA from Bordetella pertussis in bacterial strains and in nasopharyngeal samples from patients with a cough lasting at least 7 days. The assay could detect DNA from 6 CFU of B. pertussis/10 microl of sample. Results of the PCR assay were compared with those of cultures, a determination of serum antibodies against pertussis tox...

متن کامل

Detection and differentiation of Bordetella spp. by real-time PCR.

Molecular detection of Bordetella pertussis DNA is a sensitive and specific method for the rapid diagnosis of pertussis. In this study, a new molecular assay for the detection and differentiation of Bordetella spp. based on automated DNA extraction and real-time PCR was evaluated. The analytical sensitivity of the new assay was determined by Probit analysis of serial dilutions of both cloned PC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2002