Accurate in situ measurement of complex refractive index and particle size in intralipid emulsions.
نویسندگان
چکیده
A first accurate measurement of the complex refractive index in an intralipid emulsion is demonstrated, and thereby the average scatterer particle size using standard Mie scattering calculations is extracted. Our method is based on measurement and modeling of the reflectance of a divergent laser beam from the sample surface. In the absence of any definitive reference data for the complex refractive index or particle size in highly turbid intralipid emulsions, we base our claim of accuracy on the fact that our work offers several critically important advantages over previously reported attempts. First, our measurements are in situ in the sense that they do not require any sample dilution, thus eliminating dilution errors. Second, our theoretical model does not employ any fitting parameters other than the two quantities we seek to determine, i.e., the real and imaginary parts of the refractive index, thus eliminating ambiguities arising from multiple extraneous fitting parameters. Third, we fit the entire reflectance-versus-incident-angle data curve instead of focusing on only the critical angle region, which is just a small subset of the data. Finally, despite our use of highly scattering opaque samples, our experiment uniquely satisfies a key assumption behind the Mie scattering formalism, namely, no multiple scattering occurs. Further proof of our method's validity is given by the fact that our measured particle size finds good agreement with the value obtained by dynamic light scattering.
منابع مشابه
Determination of refractive indices of porcine skin tissues and intralipid at eight wavelengths between 325 and 1557 nm.
We constructed an automated reflectometry system for accurate measurement of coherent reflectance curves of turbid samples and analyzed the presence of coherent and diffuse reflection near the specular reflection angle. An existing method has been validated to determine the complex refractive indices of turbid samples on the basis of nonlinear regression of the coherent reflectance curves by Fr...
متن کاملComparison of the Effects of Intralipid 10% and 20% on Peripheral Catheter Ablation in a Pediatric Intensive Care Unit
Background: Energy deficit is a common and serious problem in pediatric intensive care units. Parenteral nutrition, either alone or in combination with enteral nutrition, can improve nutrient delivery in critically ill patients by preventing or correcting the energy deficit and improving the outcomes. Intralipid 10% and 20% are lipid emulsions, widely used in parenteral nutrition. Despite sever...
متن کاملOptical properties of fat emulsions.
We present measurements of the optical properties of six different fat emulsions from three different brands, Clinoleic, Lipovenoes and Intralipid, with fat concentrations from 10% to 30%. The scattering coefficient, the reduced scattering coefficient, and the phase function of each sample are measured for wavelengths between 350 nm and 900 nm. A method for the calculation of the particle size ...
متن کاملMeasurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry
In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...
متن کاملModeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm
Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 18 8 شماره
صفحات -
تاریخ انتشار 2013