Control strategies for harmonic mitigation and power factor correction using shunt active filter under various source voltage conditions

نویسندگان

  • Naimish Zaveri
  • Ajitsinh Chudasama
چکیده

This paper gives a new insight into the concept of load compensation using shunt active filter (SAF) under ideal and non-ideal source voltage conditions. A novel approach based on an improved instantaneous active and reactive current component method is proposed. The performance of the proposed control strategy has been compared with instantaneous reactive power theory, symmetrical component theory and dq theory. SAF has been realized by three-phase voltage source converter. Reference currents generated by control strategies has been tracked by a SAF in a hysteresis band control scheme. The performance of the proposed scheme is evaluated in terms of reactive power compensation, reduction in magnitude of source currents, compensator currents, and harmonic compensation as per IEEE-519 standard. To ascertain the viability of the proposed control algorithm, the performance is evaluated under different source voltage conditions with the IEEE Standard-1459 power definitions. Variation in magnitude as well as harmonic content of source voltage has been considered. Under balanced sinusoidal source voltage condition, all control strategies congregate to similar results. Under unbalanced sinusoidal source voltage condition, dq theory and proposed theory have shown similar performance. However, under distorted source voltage conditions, an improved instantaneous active and reactive current component theory presents superior performance. A three-phase, three-wire distribution system supplying non-linear load is considered for simulation study. Simulation results from a complete model of SAF are presented to validate and compare the control strategies. 2012 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل

Design and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter

This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...

متن کامل

Active Power Filter Design by a Novel Approach of Multi-Objective Optimization

This paper presents an innovative active power filter design method to simultaneously compensate the current harmonics and reactive power of a nonlinear load. The power filter integrates a passive power filter which is a RL low-pass filter placed in series with the load, and an active power filter which comprises an RL in series with an IGBT based voltage source converter. The filter is assumed...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016