Interobserver and intraobserver variability of measurements of uveal melanomas using standardised echography.
نویسندگان
چکیده
AIMS To report on the intraindividual and interindividual variability of tumour size (height and base diameter) measurements using standardised echography in a masked prospective study. METHODS 20 consecutive eyes of 20 patients were examined on four different visits by three experienced examiners using standardised echography. As common in standardised echography, tumour height was evaluated with A-scan technique, while transverse and longitudinal base diameter were calculated with B-scan. RESULTS Tumour height measurements using A-scan were more accurate than base diameter measurements using B-scan. The standard deviation for tumour height over all visits/measurements was 0.18 mm (A-scan), 0.79 mm for transverse, and 0.69 mm for longitudinal base diameters (B-scan). The interclass correlation coefficient (ICC) was much higher for tumour height measurements with A-scan (0.7735 for three examiners on one visit) than for transverse (0.6563) or longitudinal (0.4522) base diameter measurements with B-scan techniques. CONCLUSIONS A-scan techniques for tumour height measurements provide very reproducible results with little intraindividual and interobserver variability. As B-scan techniques for tumour base evaluation are less accurate they should be used for topographic and morphological examinations.
منابع مشابه
CLINICAL SCIENCE Interobserver and intraobserver variability of measurements of uveal melanomas using standardised echography
Aim: To report on the intraindividual and interindividual variability of tumour size (height and base diameter) measurements using standardised echography in a masked prospective study. Methods: 20 consecutive eyes of 20 patients were examined on four different visits by three experienced examiners using standardised echography. As common in standardised echography, tumour height was evaluated ...
متن کاملUltrasonographic measurement of uveal melanoma thickness: interobserver variability.
We retrospectively reviewed ultrasonographic data on 32 uveal melanomas that had been studied both at a referral institution and at our centre within a six-week period. Generally there were good correlations between ultrasonographic measurements of tumour thickness. The mean absolute difference in ultrasound measurements of tumour thickness was 0.64 mm (range 0-2.2 mm); the mean tumour thicknes...
متن کاملMeasuring blood pressure in the elderly: does atrial fibrillation increase observer variability?
OBJECTIVE To compare the interobserver and intraobserver variability of blood pressure measurements in geriatric patients in atrial fibrillation and in sinus rhythm. DESIGN Prospective assessment of blood pressure measurements carried out in random order in two groups of elderly patients by five doctors unaware of the aims of the study. SETTING Acute assessment wards for geriatric medicine,...
متن کاملبررسی پایایی درون مشاهدهگر و بین مشاهدهگر در ارزیابی هیستوپاتولوژیک لیکن پلان دهانی بر اساس معیارهای modified WHO
Background and Aims: In 1978 WHO (World health organization) formulated a histopathological definition for diagnosis of OLP (oral lichen planus). Previous studies showed that diagnosis of OLP with these criteria are not reproducible. In 2003 Van der Meij et al. represented new clinical and histopathologic definition for diagnosis of OLP known as modified WHO criteria. The purpose of this study ...
متن کاملThe interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture
Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 86 12 شماره
صفحات -
تاریخ انتشار 2002