Line parameters of 15 N 216 O from Fourier transform measurements in the 5800 - 7600 cm - 1 region and
نویسندگان
چکیده
Using FT spectra (unapodized resolution ~ 0.0056 cm −1)) of nitrous oxide isotopologue 15 N 2 16 O, the line positions and intensities have been measured for 511 lines of 8 cold and one hot bands lying between 5800 and 7600 cm −1. A multispectrum fitting procedure has been used to retrieve line parameters from 5 experimental spectra recorded at different pressures. An absolute wavenumber calibration has been performed using acetylene line positions around 6500 cm −1 and water line positions in the 7100-7300 cm −1 region. The average absolute accuracy of the line parameters obtained in this work has been estimated to be ± 0.0005 cm −1 for the line positions, 2-5% for the line intensities depending on the transitions. For each studied band, the vibrational transition dipole moment squared value and the empirical Herman-Wallis coefficients have been adjusted. Moreover the line positions measured in this work and those collected from the literature allowed the global fitting of the effective Hamiltonian parameters for this isotopologue.
منابع مشابه
EXCESS THERMODYNAMIC PROPERTIES CALCULATIONS FOR ALCOHOLS IN INERT SOLVENTS BASED ON FOURIER TRANSFORM INFRARED SPECTROSCOPY MEASUREMENTS
Self-association of alcohols; including ethanol, methanol, cyclopentanol and octanol in separate mixtures with inert solvents have been studied using FT-IR spectroscopy. Except for the band at 3640 cm–1 in the IR spectrum of the alcohols which is due to the monomer species, the presence of other bands in the region of stretching vibrational frequencies of OH (3100-3700 cm–1) are attributed to t...
متن کاملFourier Transform Infra Red Spectroscopic Studies on Epilepsy, Migraine and Paralysis
In the present paper, we have studied immunglobulin (IgG) of epileptic children, migraineous and paralytic patients. We have compared our results with normal healthy controls. We found that the bands ranges from 1151.94 to 1168.28 cm-1 due to phospholipids (P-O-C ) group appear in some of the migraineous and paralytic patients only. These bands are absent in normal and epileptic patients. The ...
متن کاملFourier-Transform Infrared Spectroscopic Comparison of Normal and Malignant Cervical Tissue Cervical Tissue.
Based on the accumulated data, FTIR spectroscopy seems to be a highly sensitive tool in cervical cancer diagnosis. We, therefore, employed this technique in a screening type of research here in Tehran. The purpose of this study was to look for the spectral pattern differences between normal and malignant cervix samples in Iranian women. Through formal and informal announcements, all gynecology ...
متن کاملFourier-Transform Infrared Spectroscopic Comparison of Normal and Malignant Cervical Tissue Cervical Tissue.
Based on the accumulated data, FTIR spectroscopy seems to be a highly sensitive tool in cervical cancer diagnosis. We, therefore, employed this technique in a screening type of research here in Tehran. The purpose of this study was to look for the spectral pattern differences between normal and malignant cervix samples in Iranian women. Through formal and informal announcements, all gynecology ...
متن کاملInfluence of synthesis parameters on the properties of nanostructured γ-Alumina using plackett-burman experimental design
Mesoporous nanostructured γ-Al2O3 powders were synthesized through multi- step precipitation procedures using the pH-swing technique. Structural and morphological characteristics in addition to the thermal behavior of the procured samples were characterized via X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), fourier transform infrared (FT-IR) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012