Optimal Control of Building HVAC Systems in the Presence of Imperfect Predictions
نویسندگان
چکیده
This paper deals with the problem of robust model predictive control of an uncertain linearized model of a building envelope and HVAC system. Uncertainty of the model is due to the imperfect predictions of internal and external heat gains of the building. The Open-Loop prediction formulation of the Robust Model Predictive Control (OL-RMPC) is known to be unnecessarily over-conservative in practice. Therefore, we adopt a Closed-Loop prediction formulation of Robust Model Predictive Control (CL-RMPC) which exploits an uncertainty feedback parameterization of the control sequence and results in a tractable formulation of the problem. To improve on the efficiency of CLRMPC we propose a new uncertainty feedback parameterization of the control input, which leads to a number of decision variables linear in time horizon as opposed to quadratic as in previous approaches. To assess our approach we compare three different robust optimal control strategies: nominal MPC which does not have a priori information of the uncertainty, OL-RMPC and CL-RMPC. We show results from a quantitative analysis of performance of these controllers at different prediction error values of the disturbance. Simulations show that CL-RMPC provides a higher level of comfort with respect to OL-RMPC while consuming 36% less energy. Moreover, CL-RMPC maintains perfect comfort level for up to 75% error in the disturbance prediction. Finally, the newly proposed parameterization maintains the performance of CL-RMPC while reducing the simulation time by an average of 30%. ∗Address all correspondence to this author.
منابع مشابه
ارزیابی کارایی سیستم تهویه مطبوع یک ساختمان اداری در شهر تهران
Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning) systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .M...
متن کاملApplication of Solar Thermal Collectors to Improve the Energy Performance of the Fresh Air HVAC Systems
In the preset study, the performance of a solar assisted heating, ventilation and air conditioning (HVAC) system in an operating theater building was studied. The yearly performances of the existing HVAC system and the system with the added solar collectors were simulated in terms of energy consumption and provided air conditions using a transient system simulation software (TRNSYS). In t...
متن کاملA Distributed Approach to Efficient Model Predictive Control of Building HVAC Systems
Model based predictive control (MPC) is increasingly being seen as an attractive approach in controlling building HVAC systems. One advantage of the MPC approach is the ability to integrate weather forecast, occupancy information and utility price variations in determining the optimal HVAC operation. However, application to largescale building HVAC systems is limited by the large number of cont...
متن کاملModel Predictive Control for Mid-Size Commercial Building HVAC: Implementation, Results and Energy Savings
The paper presents field demonstration results from the implementation of a model predictive control formulation to optimize the operation of a variable volume, dual-duct, multi-zone HVAC unit serving an existing mid-size commercial building. This full-scale study is used to estimate the benefits of advanced building control technologies that can be integrated during a retrofit. The predictive ...
متن کاملThe Empirical Assessment of Vibration in HVAC Systems
Background and purpose: Vibration caused by ventilation systems in buildings is one of the harmful physical factors that can cause harm to residents. Therefore, measuring and controlling vibration is important. Materials and Methods: In the first step of the study, the vibration accelerometer was placed on the base of a fan where the vibrations were sent toward the duct wall. A vibration asse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012