Point-of-care International Normalised Ratios: UK NEQAS experience demonstrates necessity for proficiency testing of three different monitors.

نویسندگان

  • Stephen Kitchen
  • Dianne P Kitchen
  • Ian Jennings
  • Tim A L Woods
  • Isobel D Walker
  • F Eric Preston
چکیده

External quality assessment (EQA) or proficiency testing is widely considered to be necessary for International Normalised Ratio (INR) determinations performed in conventional laboratory settings. There is increasing use of near-patient-test (NPT) or point-of-care (POC) INR devices and it is not known whether EQA is also necessary for these monitors. We report here on six years experience of proficiency testing for POC monitors used by health care professionals. Three devices were used by >10 centres who participated in the programme, the CoaguChek (CUC), the CUC-S and the TAS or Rapidpoint Coag. Not all users of the same type of monitor obtained the same INR result when analysing the same plasma sample. For the three monitors the CV of results in different centres was 11-14%. The variation between results in different centres could relate to inappropriately handled proficiency testing material, inaccuracies in the calibration of the system by the manufacturer or deterioration during transport/storage of the test strips. In each survey 10-11% of centres using POC monitors obtained INR results which were >15% different from those in other centres using the same monitors. For hospital laboratories using conventional INR techniques this figure was 12%. The relationship between INR results obtained by users of the Rapidpoint Coag or TAS monitor and results obtained by conventional techniques was not constant over the period of study. During one period INRs with TAS were 13.7% greater than with conventional methods. For the remaining three time periods results were similar. Our data suggest that the variation between INR results determined with three POC monitors show similar variation to that observed in hospital laboratories using conventional methods. Based on our data we recommend that users of these POC monitors participate regularly in an independent external proficiency testing programme.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-4: External Quality Assessment - A Necessity in The Andrology Laboratory

Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...

متن کامل

Reliability of international normalised ratios from two point of care test systems: comparison with conventional methods.

OBJECTIVE To find out how accurately two point of care test systems--CoaguChek Mini and TAS PT-NC (RapidPointCoag)--display international normalised ratios (INRs). DESIGN Comparison of the INRs from the two systems with a "true" INR on a conventional manual test from the same sample of blood. SETTING 10 European Concerted Action on Anticoagulation centres. PARTICIPANTS 600 patients on lon...

متن کامل

Quality assurance and quality control of thrombelastography and rotational Thromboelastometry: the UK NEQAS for blood coagulation experience.

Global hemostasis devices are currently being employed in operating rooms to assess the bleeding risk and outcomes for patients undergoing surgery. Two devices currently available are the TEG (Thromboelastograph; Haemoscope Corp., Niles, IL) and the ROTEM (Rotation Thromboelastometer; Pentapharm GmbH, Munich, Germany). Both measure the speed of clot formation, the strength of the clot when form...

متن کامل

Effect of international sensitivity index (ISI) of thromboplastins on precision of international normalised ratios (INR)

The contribution of the thromboplastin international sensitivity index (ISI) to the interlaboratory coefficient of variation (CV) of the international normalised ratio (INR) with individual reagents was assessed. In theory the precision of the INR should increase with lower ISI values. An empirical relation has been established between the ISI, the INR, and its CV for two rabbit thromboplastins...

متن کامل

European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

AIMS The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The present European Concerted Action on Anticoagulation (ECAA) study aimed to assess the reliability of simpler ISI calibration using lyophilised plasma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thrombosis and haemostasis

دوره 96 5  شماره 

صفحات  -

تاریخ انتشار 2006