Computer navigation versus conventional total knee replacement: no difference in functional results at two years.

We previously compared the component alignment in total knee replacement using a computer-navigated technique with a conventional jig-based method. We randomly allocated 71 patients to undergo either computer-navigated or conventional replacement. An improved alignment was seen in the computer-navigated group. The patients were then followed up post-operatively for two years, using the Knee Soc...

متن کامل

The cost-effectiveness of computer-assisted navigation in total knee arthroplasty.

BACKGROUND Total knee arthroplasty is one of the most clinically successful and cost-effective interventions in medicine. However, implant malalignment, especially in the coronal plane, is a common cause of early failure following total knee arthroplasty. Computer-assisted surgery has been employed during total knee arthroplasty to improve the precision of component alignment. The purpose of th...

متن کامل

Computer-assisted osteotomy of the lateral femoral condyle with non-constrained total knee replacement in severe valgus knees.

We describe the mid-term results of a prospective study of total knee replacement in severe valgus knees using an osteotomy of the lateral femoral condyle and computer navigation. There were 15 knees with a mean valgus deformity of 21 degrees (17 degrees to 27 degrees) and a mean follow-up of 28 months (24 to 60). A cemented, non-constrained fixed bearing, posterior-cruciate-retaining knee pros...

متن کامل

Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study.

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiologica...

متن کامل

The influence of computer-assisted surgery on rotational, coronal and sagittal alignment in revision total knee arthroplasty

BACKGROUND Despite good results of primary total knee arthroplasty (TKA), the number of revision total knee arthroplasties (rTKAs) is rising. Proper implant position is essential, since malposition leads to worse clinical outcome. In rTKA most anatomical landmarks have disappeared because of extensive bone loss, making it more difficult to adequately implant the knee prosthesis. In primary TKA,...