Outcome after transvascular transcatheter aortic valve implantation in 2016
نویسندگان
چکیده
Aims We analysed the number of procedures, complications, and in-hospital mortality rates of all patients undergoing transvascular transcatheter aortic valve implantation (TV-TAVI) in comparison to isolated surgical aortic valve replacement (iSAVR) from 2014 to 2016 in Germany. Methods and results All aortic valve procedures performed in Germany are mandatorily registered in a quality control program. More than 15 000 TV-TAVI procedures were performed in 2016 in Germany. Especially the number of post-procedural complications declined within the last few years, including new pacemaker implantations (2015: 12.6% vs. 2016: 11.4%, P = 0.002) and vascular complications (2015: 8.5% vs. 2016: 7.1%; P < 0.001). Thus, in 2016 the overall in-hospital mortality rate after TV-TAVI was 2.6%, which is for the first time numerically below that of iSAVR, which was 2.9% (P = 0.19). A stratified analysis according to the German aortic valve score shows a lower observed than expected in-hospital mortality rate for TV-TAVI (O/E 0.68). Additionally, the in-hospital mortality was significantly lower after TV-TAVI than after iSAVR in the very high- (11.3% vs. 23.6%; P < 0.001), in the high- (4.1% vs. 9.2%; P < 0.001), and in the intermediate-risk group (3.0% vs. 4.6%; P = 0.016) and was similar to that of iSAVR in low-risk patients (1.6% vs. 1.4%; P = 0.4). Conclusion The overall in-hospital mortality after TV-TAVI was numerically lower than after iSAVR in 2016 for the first time. In the low risk group in-hospital mortality was similar, whereas in all other risk groups in-hospital mortality after TV-TAVI was significantly lower than after SAVR. This is likely to contribute to a redefinition of the standard of care in the future.
منابع مشابه
Pseudomonas aeruginosa Infective Endocarditis Following Transcatheter Aortic Valve Implantation: A Note of Caution
Transcatheter aortic valve implantation (TAVI) is an alternative treatment for severe aortic valve stenosis (AS) in patients with prohibitive risk for surgical aortic valve replacement (SAVR). Prosthetic valve endocarditis (PVE) is a rare complication of this relatively novel procedure and current guidelines do not include specific recommendations for its treatment. We report a case of PVE due ...
متن کاملTranscatheter aortic valve implantation with the new-generation Evolut R™
BACKGROUND The Medtronic Evolut R (EVR) is a novel transcatheter heart valve designed to allow precise implantation at the intended position and to minimize prosthesis dysfunction as well as procedural complications. Our aim was to compare short-term functional and clinical outcomes of the new EVR with the established Medtronic CoreValve (CV) system. METHODS AND RESULTS Of 151 patients underg...
متن کاملTranscatheter Aortic Valve Implantation Compared With Surgical Aortic Valve Replacement in Low-Risk Patients.
BACKGROUND The proven efficacy of transcatheter aortic valve implantation (TAVI) in high-risk patients is leading to the expansion of its indications toward lower-risk patients. However, this shift is not supported by meaningful evidence of its benefit over surgical aortic valve replacement (SAVR). This analysis aims to describe outcomes of TAVI versus SAVR in low-risk patients. METHODS AND R...
متن کاملProsthetic valve endocarditis after transcatheter aortic valve implantation-diagnostic and surgical considerations.
Prosthetic valve endocarditis (PVE) after transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR) is a potential life threatening complication. Better understanding of the incidence, predictors, clinical presentation, diagnostic measures, complications and management of PVE may help improve TAVI long-term outcome. We report a case of TAVI-PVE in an 80-year-old...
متن کاملPlatypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation
Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI) are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 39 شماره
صفحات -
تاریخ انتشار 2018