Methods for recording electrograms of the sinoatrial node during cardiac surgery in man.

نویسندگان

  • R J Hariman
  • E Krongrad
  • R A Boxer
  • F O Bowman
  • J R Malm
  • B F Hoffman
چکیده

Recent reports have shown that it is possible to record extracellular electrograms from the rabbit and dog sinoatrial (SA) node. We applied similar techniques to record SA nodal activity in 23 patients who underwent cardiac surgery for various forms of heart disease. Both a bipolar technique, using pairs of electrodes at various interelectrode distances, and a unipolar technique, using an exploring and an indifferent electrode, were used. To record SA nodal electrograms, polarity was reversed from the conventional electrocardiographic recording; high amplification (100 microV/cm) and low-pass filters (0.15-20 Hz) were used. SA nodal electrograms were recorded from eight of 12 patients using the bipolar method and from nine of 11 patients using the unipolar method. There were no significant differences in the success rate or quality of the recording between the two methods. However, the unipolar method allowed a more accurate localization of the SA node. Human SA nodal electrograms resembled those of the dog and rabbit and showed two distinct slopes: a diastolic slope and an upstroke slope preceding the P wave of the ECG, SA conduction times were 32.4 +/- 2.8 msec (mean +/- SEM) at sinus (PP) cycle lengths of 587.6 +/- 35.6 msec for the bipolar method, and 38.2 +/- 3.2 msec at sinus (PP) cycle lengths of 712.2 +/- 50.7 msec for the unipolar method. These methods for recording of extracellular SA nodal electrograms in man may prove useful in 1) localization of the SA node during open heart surgery and 2) assessment of SA nodal function in health and disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The human sinus node electrogram: a transvenous catheter technique and a comparison of directly measured and indirectly estimated sinoatrial conduction time in adults.

To improve methods for evaluating human sinus node function (SNF), we developed a transvenous electrode catheter technique for direct recording of sinus node electrograms in adults. Sinus node electrograms (SNE) characterized by low-frequency, anatomically localized pre-P-wave potentials were obtained in 19 of 23 patients. The SNE configuration was similar to that previously found for endocardi...

متن کامل

Persistent sinus nodal electrograms during abnormally prolonged postpacing atrial pauses in sick sinus syndrome in humans: sinoatrial block vs overdrive suppression.

A transvenous electrode catheter technique was used for direct recording of bipolar sinus node electrograms during postpacing atrial pauses. Multiple repetitive local sinus node electrograms during atrial quiescence validate sinus node electrograms. Such atrial pauses with sinus node electrograms are due to sinoatrial block; atrial pauses without sinus node electrograms are due to overdrive sup...

متن کامل

The dominant pacemaker of the human heart. Antegrade and retrograde activation of the heart.

SUMMARY In 25 cases at open heart surgery, atrial and ventricular close bipolar electrograms, an atrial unipolar electrogram, and a lead-IL electrocardiogram were simultaneously monitored throughout each procedure. In six cases the ventricles or atria, or both, were paced by electrical stimulation. Although atrial activity could frequently not be clearly delineated on the lead II electrocardiog...

متن کامل

The pathophysiologic basis of fractionated and complex electrograms and the impact of recording techniques on their detection and interpretation.

Extracellular electrograms, recorded directly from the heart, are the hallmarks of invasive cardiac electrophysiology and provide information about the electric status of the underlying myocardium. These electrograms are generated by depolarization of cardiomyocytes that generates transmembrane currents in extracellular space and potential differences due to electric resistance of the extracell...

متن کامل

بررسی اثر مهار گیرنده رایانیدینی(RYR) بر فعالیت پیس‌میکری

    Background & Aim: The role of ryanodine receptor(RYR) on pacemaker activity of heart cells is controversial. Some investigators have suggested that it is obligatory, while others believe it is partial and not obligatory. The principle aim of this study was once more to characterize the role of ryanodine receptor(RyR) on the pacemaker activity of the sinoatrial node(SAN) and the atrioventric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 61 5  شماره 

صفحات  -

تاریخ انتشار 1980