Prognostic value of the ratio between prosthesis area and indexed annulus area measured by MultiSlice-CT for transcatheter aortic valve implantation procedures

نویسندگان

  • Nicolas Debry
  • Arnaud Sudre
  • Ibrahim Elquodeimat
  • Cédric Delhaye
  • Guillaume Schurtz
  • Antoine Bical
  • Mohamad Koussa
  • Thomas Modine
چکیده

BACKGROUND Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an issue. Benefit of oversizing strategies to prevent them isn't well established. We compared different level of oversizing in our cohort of consecutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. METHODS From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien(®) or Corevalve devices(®). Retrospectively, according to pre-procedural MSCT and the valve size, patients were classified into three groups: normal, moderate and severe oversizing; depending on the ratio between the prosthesis area and the annulus area indexed and measured on MSCT. Main endpoint was mid-term mortality and secondary endpoints were the Valve Academic Research Consortium (VARC-2) endpoints. RESULTS Two hundred and sixty eight patients had a MSCT and underwent TAVI procedure, with mainly Corevalve(®). While all-cause and cardiovascular mortality rates were similar in all groups, post-procedural new pacemaker (PM) implantation rate was significantly higher in the severe oversizing group (P = 0.03), while we observed more in-hospital congestive heart-failure (P = 0.02) in the normal sizing group. There was a trend toward more moderate to severe aortic regurgitation (AR) in the normal sizing group (P = 0.07). CONCLUSIONS Despite a higher rate of PM implantation, oversizing based on this ratio reduces aortic leak with lower rates of post-procedural complications and a similar mid-term survival.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT-Angiography–Based Evaluation of the Aortic Annulus for Prosthesis Sizing in Transcatheter Aortic Valve Implantation (TAVI)–Predictive Value and Optimal Thresholds for Major Anatomic Parameters

BACKGROUND/OBJECTIVES To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes. METHODS The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were exclud...

متن کامل

Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.

BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. METHODS We evaluated the theoretical impact of the measurement of the annulus diamete...

متن کامل

Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root.

BACKGROUND To retrospectively investigate the potential cause of contained rupture of the aortic root in balloon-expandable transcatheter aortic valve implantation (TAVI) by means of pre- and postinterventional multislice computed tomography. METHODS AND RESULTS Seventy-two patients (mean age 82±7 years, mean aortic valve area 0.69±0.19 cm(2)) underwent balloon-expandable TAVI using the Edwar...

متن کامل

The role of echocardiography and CT angiography in transcatheter aortic valve implantation patients

The transcatheter aortic valve implantation (TAVI) consist an alternative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echocardiography (TOE) and multislice CT (MSCT) constitute cornerstone techniques for the pre-operative management, peri-procedural guidance, follow up and recognition of possible transcat...

متن کامل

Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography.

OBJECTIVES The objectives were to compare different Doppler echocardiographic methods for the measurement of prosthetic valve effective orifice area (EOA) following transcatheter aortic valve implantation (TAVI) and to determine the factors influencing the EOA of transcatheter balloon expandable valves. BACKGROUND Previous studies have used different methods for the measurement of the valve E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2016