Combined MR-assisted motion and partial volume effects corrections – impact on PET data quantification
نویسندگان
چکیده
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA Our goal in this study was to characterize the combined effect of MR-assisted motion correction (MC) and partial volume effects correction (PVEC) on the estimation of [C]NNC112 binding potential (BP) in healthy volunteers. 29 subjects were scanned on the Siemens 3T MR-BrainPET scanner prototype. Emission data were acquired in list mode format for 90-minutes following the i.v. administration of ~8 mCi of [C]NNC112. The head attenuation map was obtained from the MPRAGE data using an atlas-based method. Head motion estimates were derived from the MR data and used to correct the PET data in LOR space before image reconstruction [1]. PVEC was applied to the motion corrected data using the region-based voxel-wise (RBV) method [2] and regions of interest (ROIs) defined from the MPRAGE images using FreeSurfer and the measured point-spread function [3]. BPnd for each of the ROIs was estimated in PMOD using the simplified reference tissue kinetic (SRTM) model and the cerebellum as a reference tissue. Maximum translations of up to 9 mm and rotations of up to 12 degrees have been observed in this group of subjects (Figure 1). Less variability in the tissue time activity curves (TACs) was noted after MC (the curves before and after MC for a representative subject are shown in Figure 2). The percentage changes in BPnd after MC and PVEC
منابع مشابه
Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer
Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...
متن کاملEffect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملImproved PET Data Quantification in an Integrated Brain MR-PET Scanner
INTRODUCTION Simultaneous MR-PET data acquisition immediately brings to mind the possibility of improving the performance of one instrument by using the information obtained from the other modality. For example, a number of aspects have to be considered in PET for obtaining a correct quantitative measure of the activity concentration in a specific voxel. First, correcting for photon attenuation...
متن کاملImpact of spillover from white matter by partial volume effect on quantification of amyloid deposition with [11C]PiB PET
High non-specific uptake of [11C]Pittsburgh compound B ([11C]PiB) in white matter and signal spillover from white matter, due to partial volume effects, confound radioactivity measured in positron emission tomography (PET) with [11C]PiB. We aimed to reveal the partial volume effect in absolute values of kinetic parameters for [11C]PiB, in terms of spillover from white matter. Dynamic data acqui...