Can we use vertical bore magnetic resonance scanners for murine cardiovascular phenotype characterization? Influence of upright body position on left ventricular hemodynamics in mice.
نویسندگان
چکیده
High resolution magnetic resonance (MR) imaging is uniquely suited for cardiovascular phenotype characterization in transgenic mice. Experimental MR scanners with the high magnetic field strength are commonly built with a vertical bore design. The hemodynamic consequences of a prolonged upright body position in anesthetized mice are, however, unknown. Thus, the purpose of this work was to investigate the influence of a vertical body position on murine systemic blood pressure and left ventricular (LV) hemodynamics over time. We studied six C57Bl/6 mice at 14-16 weeks of age (body weight, 24-28 g) under isoflurane anesthesia. Positioned supine on a 37 degrees C warming pad, a microtip catheter was advanced via the right carotid artery into the left ventricle. Continuous registration of LV hemodynamics was performed at rest and after tilting of the table to a 90-degree vertical position. After tilting, there was a transient decrease of LV systolic pressure to 96% of initial values immediately after tilting with return to baseline level within 6 min. Tilting to vertical position had no influence on LV end-diastolic pressure, heart rate, maximal rate of left ventricular pressure increase, and maximal rate of left ventricular pressure decrease. Over a follow-up period of 60 min in vertical position, there were no significant changes in murine hemodynamics. An acute change of body position is fully compensated by a normal orthostatic response in anesthetized mice. Prolonged upright body position exerts no significant changes in murine LV hemodynamics. Hence, high resolution MR studies for cardiovascular phenotype characterization in transgenic mice performed on vertical bore MR scanners allow measurements under physiologic conditions.
منابع مشابه
CINE-MR imaging of the normal and infarcted rat heart using an 11.7 T vertical bore MR system.
MR imaging is uniquely placed to non-invasively study rodent cardiac structure and function. High-field MR scanners commonly have a vertical bore, and the purpose of this work was to demonstrate CINE-MR imaging in normal and infarcted rat hearts after determining hemodynamic stability when positioned vertically for imaging. Optimisation of imaging parameters was carried out prior to assessment ...
متن کاملThe Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging
Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...
متن کاملDetecting left ventricular myocardial ischemia during intravenous dobutamine with cardiovascular magnetic resonance imaging (MRI).
Advances in computer software, scanner hardware, and hemodynamic monitoring equipment have permitted the development of cardiovascular stress testing protocols for use during intravenous Dobutamine infusions within magnetic resonance imaging (MRI) scanners. Recent studies have documented that the safety profile and clinical utility of Dobutamine/Atropine cardiac stress testing during MRI compar...
متن کاملNormalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance.
We used state of the art CMR to define ranges for normal left ventricular volumes and systolic/diastolic function normalized to the influence of gender, body surface area and age. New CMR normalized ranges were modeled and displayed in graphical form for clinical use, with normalization for body surface area, gender, and age. The determination of normality, or the severity of abnormality, depen...
متن کاملMurine orthostatic response during prolonged vertical studies: effect on cerebral blood flow measured by arterial spin-labeled MRI.
High-field MRI scanners are, in principle, well suited for mouse studies; however, many high-field magnets employ a vertical design that may influence the physiological state of the rodent. The purpose of this study was to investigate the orthostatic response of cerebral blood flow (CBF) in mice during a prolonged MR experiment in the vertical position. Arterial spin-labeled (ASL) MRI was perfo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 3 4 شماره
صفحات -
تاریخ انتشار 2001