Histologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography.
نویسندگان
چکیده
PURPOSE To compare ultrahigh-resolution optical coherence tomography (OCT) cross-sectional images of the pig retina with histology, to evaluate the potential of ultrahigh-resolution OCT for enhanced visualization of intra- and subretinal structures. METHODS Ultrahigh-resolution OCT images were acquired with 1.4- micro m axial x 3- micro m transverse resolution from in vitro posterior eyecup preparations of the domestic pig. Frozen sections were obtained in precise alignment with OCT tomograms, by using major blood vessels as orientation markers and were counterstained with cresyl violet or unstained and examined by differential interference contrast microscopy. Micrographs from histologic sections were linearly scaled to correct for tissue shrinkage and compared with OCT tomograms. RESULTS In the proximal retina, ultrahigh-resolution OCT signal bands directly corresponded to the main retinal layers. For the wavelength region used ( approximately 800 nm), axodendritic layers (nerve fiber layer, inner and outer plexiform layers) were more reflective than cell body layers (ganglion cell layer, inner nuclear layer, outer nuclear layer). In the distal retina, substructures of the photoreceptor layer such as the interface between inner and outer segments were visualized, and the retinal pigment epithelium, the choriocapillaris, and superficial choroid layers were resolved. In addition, the time sequence of a retinal detachment event was monitored by ultrahigh-resolution OCT. CONCLUSIONS In vitro ophthalmic ultrahigh-resolution OCT imaging reveals retinal morphology with unprecedented detail. The specific assignment of OCT signal patterns to retinal substructures provides a basis for improved interpretation of in vivo ophthalmic OCT tomograms of high clinical relevance.
منابع مشابه
Ultrahigh-resolution optical coherence tomography with a diode-pumped broadband Cr(3+):LiCAF laser.
Ultrahigh resolution optical coherence tomography (OCT) is performed with a broadband, Kerr-lens mode-locked, diode-pumped Cr(3+):LiCAF laser. The laser source has a bandwidth of 89 nm with an output power of 37 mW. OCT imaging is demonstrated with 4.5 microm axial resolution in air or 3.4 microm in tissue. In vivo imaging of the human retina is demonstrated. Ultrahigh resolution OCT images fro...
متن کاملThree-dimensional adaptive optics ultrahigh-resolution optical coherence tomography using a liquid crystal spatial light modulator
A liquid crystal programmable phase modulator (PPM) is used as correcting device in an adaptive optics system for three-dimensional ultrahigh-resolution optical coherence tomography (UHR OCT). The feasibility of the PPM to correct high order aberrations even when using polychromatic light is studied, showing potential for future clinical use. Volumetric UHR OCT of the living retina, obtained wi...
متن کاملIn vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography.
An ultrahigh-speed spectral domain optical coherence tomography (SD-OCT) system is presented that achieves acquisition rates of 29,300 depth profiles/s. The sensitivity of SD-OCT and time domain OCT (TD-OCT) are experimentally compared, demonstrating a 21.7-dB improvement of SD-OCT over TD-OCT. In vivo images of the human retina are presented, demonstrating the ability to acquire high-quality s...
متن کاملIn vivo volumetric imaging of chicken retina with ultrahigh-resolution spectral domain optical coherence tomography
The chicken retina is an established animal model for myopia and light-associated growth studies. It has a unique morphology: it is afoveate and avascular; oxygen and nutrition to the inner retina is delivered by a vascular tissue (pecten) that protrudes into the vitreous. Here we present, to the best of our knowledge, the first in vivo, volumetric high-resolution images of the chicken retina. ...
متن کاملIntact retinal tissue and retinal pigment epithelium identified within a coloboma by high-speed, ultrahigh-resolution optical coherence tomography.
PURPOSE The purpose of this study was to report on a posterior segment coloboma manifesting unusual morphology as determined by high-speed, ultrahigh-resolution optical coherence tomography imaging. METHODS A 47-year-old woman with bilateral colobomas was evaluated by fundus examination and high-speed, ultrahigh-resolution optical coherence tomography imaging. RESULTS Imaging with high-spee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 44 4 شماره
صفحات -
تاریخ انتشار 2003