Assessment of calvarial structure motion by MRI

نویسندگان

  • William T Crow
  • Hollis H King
  • Rita M Patterson
  • Vincent Giuliano
چکیده

BACKGROUND Practitioners of manual medicine/manual therapy (MM/MT) who utilize techniques thought to have some impact upon and move the solid structures of the human head have been criticized for lack of evidence of cranial bone motion. The present study utilized magnetic resonance imagery (MRI) technology to address the question of whether or not inherent (non-operator initiated) calvarial structure motion can be assessed. METHODS SUBJECTS Twenty healthcare professionals, (physicians, nurses, medical students, pharmacists) between the ages of 24 and 52 were recruited. Seven females (ages 25-47, mean age 36.7) and 13 males (ages 25-53, mean age 31.2) volunteered. Technology: MRI scans were acquired at 450 ms per slice, in a 1.5 Tesla Signa Excite HD closed MRI system. The same scan prescription was repeated serially every 45 seconds to obtain eight serial slices for each subject. Image analysis was accomplished using ImageJ software (ImageJ 1.33 u National Institutes of Health, USA). Data from all eight images for each of the 20 subjects were analyzed to determine the two images with the largest differences in the parameters measured. RESULTS Difference values for the measures of area, width, height, major axis, and feret were statistically different whereas the measures for perimeter and minor axis were not. However, only the difference values for area were both statistically different (p < 0.003) and exceeded the resolution threshold of 0.898 mm/pixel. DISCUSSION The statistically significant difference value for area is suggestive of inherent motion in calvarial structures, and adds to the body of evidence supportive of biomechanically measurable calvarial structure motion in general. That the total intracranial area appeared to expand and recede was consistent with theory and prior studies suggestive of calvarial structure motion due to intracranial fluid volume changes. CONCLUSION The use of MRI technology was able to demonstrate calvarial structure motion at a level exceeding the resolution threshold, and provides a means for further research on phenomena related to the cranial concept. It may be just a matter of time until increased resolution of MRI technology and image analysis provide the ability to examine more detailed areas of specific cranial bone motion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Real Ground Motion Records in Performance Assessment of RC Buildings

Reinforced concrete frame buildings with Open Ground Story (OGS) are one of the most common building configurations in urban habitat. These configurations are known to be vulnerable to seismic excitations, primarily due to the sudden loss in strength in the ground story and differential stiffness distribution throughout the structure. The differential stiffness distribution is attributed primar...

متن کامل

Seismic Damage Assessment of RC Buildings Subjected to the Rotational Ground Motion Records Considering Soil-Structure Interaction

The significance of the seismic rotational components have been overlooked in the seismic evaluation of structural behavior. As researchers have measured seismic components more accurately using sensitive rotational velocity sensor, it was observed that the magnitude of rotational components is considerable and could not be neglected. Hence, some parts of seismic damage or failure of structures...

متن کامل

An Adaptive Hierarchical Method Based on Wavelet and Adaptive Filtering for MRI Denoising

MRI is one of the most powerful techniques to study the internal structure of the body. MRI image quality is affected by various noises. Noises in MRI are usually thermal and mainly due to the motion of charged particles in the coil. Noise in MRI images also cause a limitation in the study of visual images as well as computer analysis of the images. In this paper, first, it is proved that proba...

متن کامل

گزارش یک مورد کیست استخوانی آنوریسمال سینوس اتموئید

    Introduction: Aneurysmal bone cyst(ABC) is a benign lesion with variable and expansile growth that can occur in any part of the skeletal, mainly in long bones and vertebra. ABC in paranasal sinuses is rare with only 7 previous cases having been describes in the ethmoid, sphenoid and frontal sinuses. Case Report: We present a case of ethmoidal sinus ABC in a 15-year-old female presenting nas...

متن کامل

Design and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging

Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Osteopathic Medicine and Primary Care

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009