Pregnancy outcome and management of women with an implantable cardioverter defibrillator: a single centre experience.

نویسندگان

  • Pia K Schuler
  • Anna Herrey
  • Angie Wade
  • Ruth Brooks
  • Donald Peebles
  • Pier Lambiase
  • Fiona Walker
چکیده

AIMS With improved survival of patients with congenital and inherited heart disease, there is now a younger cohort of patients with an implantable cardioverter defibrillator (ICD) for the prevention and treatment of ventricular dysrrhythmias. Young women with such disorders often wish to embark on pregnancy, but pregnancy outcome data for this group is sparse. We therefore evaluated pregnancy outcome in patients with heart disease and an ICD in situ. METHODS AND RESULTS A retrospective analysis was performed on all women with an ICD in situ, who had pregnancy care provided by the specialist maternal cardiology service at University College London Hospitals. Data for 19 pregnancies in 14 women were collected. The underlying cardiac diagnoses were congenital heart disease (one), familial hypertrophic cardiomyopathy (eight), familial dilated cardiomyopathy (one), inherited long QT syndrome (one), and idiopathic cardiac arrest (one). Three women had moderate impairment of the left ventricular systolic function (ejection fraction <45%), in the remainder it was normal. Nine ICD implants were for primary prevention of sudden cardiac death (64%) and five for secondary prevention (36%). Of the 19 pregnancies, 18 continued beyond 24 weeks gestation with 18 live births. In eight pregnancies there were medical or device-related complications (42.9%) as follows: arrhythmias (four) (21.1%), heart failure (two) (9.1%), ICD shocks (one) (5.3%), atrial lead fracture (one) (5.3%), and lead-related thrombus (one) (5.3%). There were no inappropriate device shocks or therapies. CONCLUSIONS Women with heart disease and an ICD implant can have a good outcome during pregnancy but medical and device complications are not uncommon.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

Implantable cardioverter-defibrillator in pregnant women with hypertrophic cardiomyopathy.

We describe the successful implantation of a cardioverter-defibrillator (ICD) in two pregnant women with hypertrophic cardiomyopathy at high risk. The indication of ICD and the necessary care for ICD implantation during pregnancy are discussed and were the main objectives of this case report.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 14 12  شماره 

صفحات  -

تاریخ انتشار 2012