A Generalized Class of Stationary Frame-Current Controllers for Grid-Connected AC–DC Converters

نویسندگان

  • Peter W. Lehn
  • J. George Hwang
چکیده

Within power systems, high-power pulsewidth-modulated ac–dc converters are used in flexible ac transmission systems controllers and for interfacing renewable energy sources to the grid. These converters traditionally employed PI controllers designed in the synchronous -frame with decoupling of and axes. Recently, stationary -frame proportional-resonant (PR) controllers have been proposed. Though both types of control are suitable for the regulation of three-phase converters, the PR controller displays steady-state and dynamic behavior that differs significantly from that of decoupled -frame controllers. This paper derives a stationary frame controller that is the exact equivalent of the commonly used synchronous frame controller with decoupling. The new stationary frame “PRX2” controller consists of a proportional (P), a resonant (R), and two cross-coupling components. The PRX2 controller offers identical transient and steady-state performance and has the same frequency response as the decoupled synchronous frame PI controller. Unlike other stationary frame controllers containing resonant components, the PRX2 controller is unique because it contains a cross-coupling feedback component, which accounts for the behavior of the decoupling branches present in synchronous frame controllers. It is shown that ignoring this decoupling component greatly increases the controller’s sensitivity to frequency variation. Numerous stationary frame controllers, including the common PR controller, may be derived from the general PRX2 controller.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of the Min-Projection and the Model Predictive Strategies for Current Control of Three-Phase Grid-Connected Converters: a Comparative Study

This paper provides a detailed comparative study concerning the performance of min-projection strategy (MPS) and model predictive control (MPC) systems to control the three-phase grid connected converters. To do so, first, the converter is modeled as a switched linear system. Then, the feasibility of the MPS technique is investigated and its stability criterion is derived as a lower limit on th...

متن کامل

Novel application of hybrid Perovskite materials in grid-connected photo-voltaic cells

In this paper, the novel application of organic/inorganic perovskite hybrid materials isproposed for grid-connected Photo-voltaic (PV) cells. The perovskite hybrid cells attracted a lot of interest due to their potential in combining advantages of both components. Looking to the future, there is no doubt that these new generations of hybrid materials, born from the very fruitful activitie...

متن کامل

On The Analytical Tuning Of Controllers for Grid-Coupled Voltage Source Converter: Frequency Analysis

The grid conditions determine what the output voltage of a grid connected power converters should be. Control of the output voltage of these power converters is by this condition not possible. The power converters are however, not directly connected to the grid. The conventional method to interface these converters to the grid is through filters [1,2]. The duty of the filter is to reduce the cu...

متن کامل

On The Analytical Tuning Of Controllers for Grid-Coupled Voltage Source Converter: Frequency Analysis

The grid conditions determine what the output voltage of a grid connected power converters should be. Control of the output voltage of these power converters is by this condition not possible. The power converters are however, not directly connected to the grid. The conventional method to interface these converters to the grid is through filters [1,2]. The duty of the filter is to reduce the cu...

متن کامل

On The Analytical Tuning Of Controllers for Grid-Coupled Voltage Source Converter: Frequency Analysis

The grid conditions determine what the output voltage of a grid connected power converters should be. Control of the output voltage of these power converters is by this condition not possible. The power converters are however, not directly connected to the grid. The conventional method to interface these converters to the grid is through filters [1,2]. The duty of the filter is to reduce the cu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010