24-year follow-up on a patient with a Blalock-Taussig anastomosis at 23 months.
نویسنده
چکیده
منابع مشابه
Surgical palliation of tricuspid atresia.
In the 20-year period ending December 31, 1973 we operated on 105 patients for palliation of tricuspid atresia (TA) with reduced pulmonary blood flow. Pott's anastomosis (85), Blalock-Taussig anastomosis (19), intrapericardial aorta (Ao)-to-right pulmonary artery (RPA) (18), Glenn procedure (3) and miscellaneous shunts (2) have been used. Of patients undergoing operation more than 15 years ago,...
متن کاملTen to thirteen year follow-up on patients after a Blalock-Taussig operation.
IN 1956 White, McNamara, Bauersfeld, and Taussig1 reported a 5 to 8 year follow-up on 224 patients with a tetralogy of Fallot who had been improved by a Blalock-Taussig operation, and on whom we had eomplete information. By complete information we meant not only that we knew whether the patient was living or dead, improved or no longer improved, but also for all those who were living we knew th...
متن کاملPulmonary vascular disease complicating the Blalock-Taussig anastomosis.
The pulmonary vascular bed was evaluated following a Blalock-Taussig shunt performed in 36 patients for decreased pulmonary blood flow. The time of follow-up ranged from one to 21 years after operation. No patients developed severe pulmonary changes in less than eight years after institution of the shunt. Ten of 20 patients having a shunt eight years or longer developed some degree of pulmonary...
متن کاملTen to Thirteen Year Follow - up on Patients after a Blalock - Taussig Operation By HELEN
IN 1956 White, McNamara, Bauersfeld, and Taussig1 reported a 5 to 8 year follow-up on 224 patients with a tetralogy of Fallot who had been improved by a Blalock-Taussig operation, and on whom we had eomplete information. By complete information we meant not only that we knew whether the patient was living or dead, improved or no longer improved, but also for all those who were living we knew th...
متن کاملInfection of modified Blalock shunts.
A left-sided interposition graft (modified Blalock-Taussig anastomosis) was constructed with polytetrafluoroethylene in a three month old child with tetralogy of Fallot. This shunt thrombosed and a replacement shunt became the site of chronic Pseudomonas infection. The second anastomosis was excised and a third interposition graft was inserted on the right side because the anatomy was unsuitabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 34 1 شماره
صفحات -