Asymptotic Stability of Gaver’s Parallel System Attended by a Cold Standby Unit and a Repairman with Multiple Vacations
نویسنده
چکیده
We investigate Gaver’s parallel system attended by a cold standby unit and a repairman with multiple vacations. By analysing the spectral distribution of the system operator and taking into account the irreducibility of the semigroup generated by the system operator we prove that the dynamic solution converges strongly to the steady state solution. Thus we obtain asymptotic stability of the dynamic solution of the system.
منابع مشابه
On the Idle Time of a Repairman Attending a Renewable Cold Standby System
We consider a basic cold standby system attended by a single repairman. The system satisfies the usual conditions (i.i.d. random variables, perfect repair, instantaneous and perfect switch, queueing). The operative unit has a constant failure rate and an arbitrary repair time distribution. We analyse the idle time of the repairman during the survival time of the system. Finally, as an example, ...
متن کاملReliability Analysis of Redundant Repairable System with Degraded Failure
This investigation deals with the transient analysis of the machine repair system consisting of M-operating units operating under the care of single repairman. To improve the system reliability/availability, Y warm standby and S cold standby units are provided to replace the failed units. In case when all spares are being used, the failure of units occurs in degraded fashion. In such situation ...
متن کاملOn the Reliability of a Renewable Multiple Cold Standby System
Apart from important but particular cases, such as state-dependent exponential distributions, for example, [1, 4] or an arbitrary repair time distribution [12], the reliability analysis of multiple cold standby systems is far from complete. We present a general reliability analysis of a basic multiple cold standby system attended by a single repairman, henceforth called a K-system. The K-system...
متن کاملA Functional Equation Related to a Multiple Cold Standby System
We consider a basic multiple cold standby system attended by a single repairman. The system satisfies the usual conditions (i.i.d. random variables, perfect repair, instantaneous and perfect switch, queueing). We analyse the long-run availability of the system based on a functional equation valid in the complex plane. The solution is constructed by means of a Cauchy-type integral. As an example...
متن کاملA cold system with two different components and a single vacation of the repairman
In this paper, we model a cold standby repairable system with one repairman. Suppose that the system consists of two dissimilar components and one repairman, in which component 1 is the major working unit and component 2 is the cold stand-by unit, component 1 has priority in use and repair; then the repairman takes a single vacation. Under these assumptions , we derive a model of partial differ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015