Study of the Energy Modulated Electron Cyclotron Resonance Ion Source for the Coupled Rfq-sfrfq Cavity

نویسندگان

  • W. L. Xia
  • Z. Wang
  • Y. R. Lu
  • K. Zhu
  • S. L. Gao
  • J. Zhao
  • X. Peng
  • X. Q. Yan
  • Z. Y. Guo
  • J. E. Chen
چکیده

The coupled RFQ and SFRFQ cavity has been manufactured and tested recently. According to the beam dynamic design, the input He beam within 120° phase width is designed for the cavity to achieve over 98% transmission efficiency. An energy modulated electron cyclotron resonance (ECR) ion source was proposed and simulated. To achieve the 1% energy modulation on the 30keV direct current (DC) beam, two simplified RF power feeding structures for beam bunching were studied. The simulations show positive results as well as the bunched beam is achieved by the energy modulated ECR ion source.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commissioning Results and Progress of a Helium Injector for Coupled RFQ and SFRFQ Project at Peking University

At Peking University (PKU) a new helium injector for coupled radio frequency quadrupole(RFQ) and separated function radio frequency quadrupole(SFRFQ) within one cavity, so called as coupled RFQ & SFRFQ, was designed recently[1]. It will provide a 30keV 10mA He beam whose emittance is less than 0.15 π.mm.mrad for the accelerator. It is a combination of a 2.45GHz PKU permanent magnet electron cyc...

متن کامل

A Helium Injector for Coupled Rfq and Sfrfq Cavity Project at Peking University

A new acceleration structure named as coupled radio frequency quadrupole and separated function radio frequency quadrupole cavity (Coupled RFQ & SFRFQ) is under design at Peking University (PKU). A pulsed or CW He beam injector will be needed to transport 30 keV 20 mA He beam and normalized rms emittance less than 0.15 pi.mm.mrad for this composited type cavity. For pulsed mode, the factor is 1...

متن کامل

Simulation study of LEBT for transversely coupled beam from an ECR ion source.

A Low-Energy intense-highly charged ion Accelerator Facility (LEAF) program has been launched at Institute of Modern Physics. This accelerator facility consists of a superconducting Electron Cyclotron Resonance (ECR) ion source, a Low Energy Beam Transport (LEBT) system, and a Radio Frequency Quadrupole (RFQ). It is especially of interest for the extracted ion beam from the ECR ion source, whic...

متن کامل

Electron-beam extraction system for the Frankfurt 14 GHz electron cyclotron resonance ion source

A new concept to assist in the extraction of ion beams from an electron cyclotron resonance ion source ~ECRIS! by the injection of an electron beam from the extraction side into the ion-source plasma is proposed. In this article, the construction of a test setup is described and first results of experiments with this setup at the 14 GHz ECRIS of the Frankfurt ECRIS-~ve!RFQ facility are reported...

متن کامل

Implementation of a Superconducting Electron Beam Ion Source into the Hit Ion Source Testbench

Cancer therapy with light heavy ions is now a well proven technology. Almost all facilities are running Electron Cyclotron Resonance Ion Sources (ECRIS) to produce carbon ions and protons as well. In the 1990’s the idea of using a Electron Beam Ion Source (EBIS) was proposed [1]. Some proof of principle measurements were carried out [2] but the application of EBIS ion sources in radiation facil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015