The use of finite element analysis to model bone-implant contact with basal implants.

نویسندگان

  • Stefan Ihde
  • Tomas Goldmann
  • Lucie Himmlova
  • Zoran Aleksic
چکیده

OBJECTIVE The purpose of this study was to develop a model that accurately represents the interface between bone and basal implants throughout the healing process. STUDY DESIGN The model was applied to the biological scenario of changing load distribution in a basal implant system over time. We did this through finite element analysis (FEA, or finite element method [FEM]), using multiple models with changing bone-implant contact definitions, which reflected the dynamic nature of the interface throughout the bony healing process. RESULTS In the simple models, peak von Mises stresses decreased as the bone-implant-contact definition was changed from extremely soft contact (i.e., immature bone during early loading) to hard contact (i.e., mature bone). In upgraded models, which more closely approximate the biological scenario with basal dental implant, peak von Mises stresses decreased at the implant interface; however, they increased at the bone interface as a harder contact definition was modeled. Further, we found a shift in peak stress location within the implants during different contact definitions (i.e., different stages of bony healing). In the case of hard contact, the peak stress occurs above the contact surface, whereas in soft contact, the stress peak occurs in the upper part of the contact area between bone and the vertical shaft of the implant. Only in the extreme soft contact definitions were the peak stresses found near the base plate of the implant. CONCLUSION Future FEM studies evaluating the functional role of dental implants should consider a similar model that takes into account bone tissue adaptations over time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics

دوره 106 1  شماره 

صفحات  -