Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease
نویسندگان
چکیده
OBJECTIVE To evaluate the diagnostic accuracy of a dual-source computed tomography (DSCT) coronary angiography, with a particular focus on the effect of heart rate and calcifications. MATERIALS AND METHODS One hundred and nine patients with suspected coronary disease were divided into 2 groups according to a mean heart rate (< 70 bpm and >or= 70 bpm) and into 3 groups according to the mean Agatston calcium scores ( 400). Next, the effect of heart rate and calcification on the accuracy of coronary artery stenosis detection was analyzed by using an invasive coronary angiography as a reference standard. Coronary segments of less than 1.5 mm in diameter in an American Heart Association (AHA) 15-segment model were independently assessed. RESULTS The mean heart rate during the scan was 71.8 bpm, whereas the mean Agatston score was 226.5. Of the 1,588 segments examined, 1,533 (97%) were assessable. A total of 17 patients had calcium scores above 400 Agatston U, whereas 50 had heart rates >or= 70 bpm. Overall the sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for significant stenoses were: 95%, 91%, 65%, and 99% (by segment), respectively and 97%, 90%, 81%, and 91% (by artery), respectively (n = 475). Heart rate showed no significant impact on lesion detection; however, vessel calcification did show a significant impact on accuracy of assessment for coronary segments. The specificity, PPV and accuracy were 96%, 80%, and 96% (by segment), respectively for an Agatston score less than 100% and 99%, 96% and 98% (by artery). For an Agatston score of greater to or equal to 400 the specificity, PPV and accuracy were reduced to 79%, 55%, and 83% (by segment), respectively and to 79%, 69%, and 85% (by artery), respectively. CONCLUSION The DSCT provides a high rate of accuracy for the detection of significant coronary artery disease, even in patients with high heart rates and evidence of coronary calcification. However, patients with severe coronary calcification (> 400 U) remain a challenge to diagnose.
منابع مشابه
ارزش تشخیصی -MSCT آنژیوگرافی با تکنولوژی 64 - Sliceدر مقایسه با آنژیوگرافی مرسوم در شناسایی بیماری شریان کرونری
Background: Multislice computed tomography (MSCT) is a noninvasive method of detecting coronary artery disease (CAD). The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT) in daily practice, without patient selection. Methods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA). The CT system The...
متن کاملCoronary artery calcium (CAC) score – a prognostic tool in coronary artery disease?
Introduction: The aim of this study was to evaluate the impact of measurement of coronary artery calcification score (CAC) in patients with suspected coronary artery disease (CAD) and a normal myocardial perfusion scan. Methods: In a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of CAD and a normal perfusion scan. In ...
متن کاملAssociation between Coronary Artery Sclerosis and Dental Pulp Calcification in Patients Attending Sari Touba Clinic, 2019
Background and purpose: Coronary artery disease is a major cause of mortality, morbidity, and disability in society and patients incur high expenditure on treatment. Pulp stones are ectopic calcifications of the pulp vessel walls, so, they can have similar pathogenesis as those of other organs and coronary atherosclerosis. The purpose of this study was to investigate the correlation between cor...
متن کاملProspective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...
متن کاملMyocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2009