Static and dynamic human flexor tendon-pulley interaction.

نویسندگان

  • Andreas Schweizer
  • Beat K Moor
  • Ladislav Nagy
  • Jess G Snedeker
چکیده

The aim of the study was to investigate the influence of a preceding flexion or extension movement on the static interaction of human finger flexor tendons and pulleys concerning flexion torque being generated. Six human fresh frozen cadaver long fingers were mounted in an isokinetic movement device for the proximal interphalangeal (PIP) joint. During flexion and extension movement both flexor tendons were equally loaded with 40N while the generated moment was depicted simultaneously at the fingertip. The movement was stopped at various positions of the proximal interphalangeal joint to record dynamic and static torque. The static torque was always greater after a preceding extension movement compared to a preceding flexion movement in the corresponding same position of the joint. This applied for the whole arc of movement of 0-105 degrees . The difference between static extension and flexion torque was maximal 11% in average at about 83 degrees of flexion. Static torque was always smaller than dynamic torque during extension movement and always greater than dynamic torque during flexion movement. The kind of preceding movement therefore showed an influence to the torque being generated in the proximal interphalangeal joint. The effect could be simulated on a mechanical finger device.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finger injuries in extreme rock climbers. Assessment of high-resolution ultrasonography.

Dynamic high-resolution ultrasonography findings obtained in 34 extreme rock climbers with finger injuries were compared with those in 20 healthy volunteers. Thicknesses of the flexor tendon and A-2 flexor tendon pulley system were measured at the base of the proximal phalanx. The distance between the tendon and phalanx was evaluated with the finger in extension and in forced flexion as a measu...

متن کامل

Comparison of the Thickness of Pulley and Flexor Tendon Between in Neutral and in Flexed Positions of Trigger Finger

OBJECTIVE This study aims to compare the morphology of the A1 pulley and flexor tendons in idiopathic trigger finger of digits other than the thumb between in neutral position and in the position with the interphalangeal joints full flexed and with the metacarpophalangeal (MP) joint 0° extended (hook grip position). METHOD A total of 48 affected digits and 48 contralateral normal digits from ...

متن کامل

Ganglion of the Flexor Tendon Sheath at the A2 Pulley - Case Report

There are few reported cases of flexor tendon sheath ganglion arising from the A2 pulley. We report a case of a flexor tendon sheath ganglion in a 17-year old female who presented with pain, triggering and a swelling at the base of her right ring finger. During the excision biopsy, a ganglion measuring 0.5×0.8×0.4 cm in size was removed from the A2 pulley area.

متن کامل

Reverse Trigger Finger: Does it exist? A Case Report

Trigger finger is a common condition, occurs primarily at the A1 pulley and tenosynovitis is the usual cause. However, although rare, triggering of the flexor tendon can occur in other areas. We present previously unreported condition in adult: triggering at the distal end of A2 pulley, which was caused by nodular thickening of the flexor digitorium profondus tendon with degeneration. A 79-year...

متن کامل

Safe Treatment of Trigger Thumb With Longitudinal Anatomic Landmarks

OBJECTIVE Stenosing tenosynovitis of the thumb flexor tendon sheath is also known as trigger thumb. It is an inflammatory process that involves the flexor tendon sheath at the A1 pulley. Successful percutaneous or open treatment of trigger thumb depends on the ability of the clinician to properly predict the location of the A1 pulley. Longitudinal anatomic landmarks can facilitate safe treatmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanics

دوره 42 12  شماره 

صفحات  -

تاریخ انتشار 2009