Primary Migration of Fully-threaded Acetabular Prostheses

نویسندگان

  • A ROENTGEN
  • JOHAN KARRHOLM
چکیده

We investigated the fixation of fully-threaded cementless acetabular prostheses in 20 patients with osteoarthritis, measuring the migration of the cup using roentgen stereophotogrammetric analysis (RSA). All the cups migrated proximally, 13 moved laterally or medially, and nine moved anteriorly or posteriorly in the first two postoperative years, the average migration being 1.1 to 1.4 mm in either direction. Rotatory movements of up to 5.7#{176} were found in nine of the 13 hips where this analysis could be performed. Movements of cobalt-chrome (12) and titanium alloy (8) cups did not differ significantly. Seventeen of the 20 patients had some pain two years after the operation. The migration of the prostheses indicates that ‘osseointegration’ had not occurred. The combination of this with persistent pain suggests that the long-term results will be unfavourable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The measurement of migration of the acetabular component of hip prostheses.

Individual components of a total hip replacement are difficult to evaluate and quantify. We have studied the assessment of the acetabular component, and conclude that the measurement of migration allows the comparison of implants, although there is no established link between migration and significant loosening. A method of measurement based on clinical radiographs has been developed, and its l...

متن کامل

The Influence of Tribological Pairings and Other Factors on Migration Patterns of Short Stems in Total Hip Arthroplasty

Over the last decade, the number of short stem total hip arthroplasty procedures has increased. Along with the possible benefits associated with short stems is a smaller implant-bone contact surface, which may have a negative influence on primary stability and impair osseointegration. Previous studies observed migration of short stems, especially within the first three months. The variables tha...

متن کامل

Middle-term results of threaded acetabular cups. High failure rates five years after surgery.

We report our results using three different threaded acetabular components (Mecring A, Mecring B and Weill) in 715 hips with a follow-up of between one and ten years (median: 99.1, 56.5, 38.3 months, respectively). All cups were implanted with one type of cementless stem. The clinical results were good or acceptable in about 70% of the hips, but signs of loosening with radiolucency and/or migra...

متن کامل

Five-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry.

BACKGROUND Articular Surface Replacement (ASR) hip prostheses, which have metal-on-metal bearing surfaces, were manufactured by DePuy Orthopaedics (Warsaw, Indiana) for use in both conventional total hip arthroplasty and hip resurfacing. Both the ASR XL Acetabular System and the ASR Hip Resurfacing System were recently recalled worldwide by the manufacturer. This report summarizes an analysis b...

متن کامل

Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005