Trends in Fidelis lead survival: transition from an exponential to linear pattern of lead failure over time.
نویسندگان
چکیده
BACKGROUND The Sprint Fidelis implantable cardioverter-defibrillator lead was recalled in 2007 because of an levated risk of lead fracture. Several studies have demonstrated an accelerating risk of lead failure over time. We sought to identify predictors and characterize trends of Fidelis lead failure. METHODS AND RESULTS We evaluated 604 Fidelis leads with ≥ 90 days of follow-up implanted at our institution. Fidelis lead survival was analyzed by the Kaplan-Meier method. Analysis of log-log plots of cumulative hazard plots was performed to assess changes in lead failure rate over time. During follow-up of 3.3 ± 1.7 years, 51 (8.4%) Fidelis lead failures were identified. The 3-year and 5-year Fidelis lead survival rates were 93.5% and 85.3%, respectively. Female sex was the only significant predictor of lead failure (heart rate, 2.1; 95% CI, 1.1-3.9; P<0.0001). The rate of lead failure initially increased exponentially with a power of 2.3 (95% CI, 2.22-2.43; P<0.0001). However, log-log analysis of cumulative hazard for leads functioning at 2 and 4 years revealed a stable rate of failure of 4.5%/year. Mathematical modeling of the Fidelis lead failure demonstrated a transition from an exponential to linear pattern of lead failure at 2.9 years. CONCLUSIONS After 3 years, failure rates of Fidelis leads stabilize but at a significantly elevated rate. Female sex is associated with a doubling of the risk of Fidelis lead failure. These findings have implications for Fidelis lead management decisions that are based on the prediction of lead failure risk.
منابع مشابه
Arrhythmia/Electrophysiology Clinical Predictors of Fidelis Lead Failure Report From the Canadian Heart Rhythm Society Device Committee
Background—Approximately 268 000 Fidelis leads were implanted worldwide until distribution was suspended because of a high rate of early failure. Careful analyses of predictors of increased lead failure hazard are required to help direct future lead design and also to inform decision making on lead replacement. We sought to perform a comprehensive analysis of all potential predictors in a multi...
متن کاملClinical predictors of Fidelis lead failure: report from the Canadian Heart Rhythm Society Device Committee.
BACKGROUND Approximately 268,000 Fidelis leads were implanted worldwide until distribution was suspended because of a high rate of early failure. Careful analyses of predictors of increased lead failure hazard are required to help direct future lead design and also to inform decision making on lead replacement. We sought to perform a comprehensive analysis of all potential predictors in a multi...
متن کاملMulti-institutional study of implantable defibrillator lead performance in children and young adults: results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) study.
BACKGROUND Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. We sought to determine the outcomes of ICD leads in pediatric and congenital heart disease patients. METHODS AND RESULTS The Pediatric Lead Extractability and S...
متن کاملLearning from implantable cardioverter-defibrillator leads in children.
I f you want something broken, give it to your kid. That truism applies to many items, from toys to technology. The article describing the results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) study by Atallah et al 1 in this issue of Circulation provides sobering but important evidence that this also applies to implantable cardioverter-defibrillator (ICD) leads. Most IC...
متن کاملArrhythmia/Electrophysiology Longevity of Sprint Fidelis Implantable Cardioverter- Defibrillator Leads and Risk Factors for Failure Implications for Patient Management
Background—Sprint Fidelis (Fidelis) implantable cardioverter-defibrillator leads are prone to fractures that have caused adverse events, primarily inappropriate shocks, and a few reported deaths. More than 100 000 patients have Fidelis leads. No independent multicenter long-term performance information exists for this lead, and single-center studies suggest that certain patients are at increase...