Liquid-phase broadband cavity-enhanced absorption spectroscopy measurements in a 2 mm cuvette.
نویسندگان
چکیده
A novel implementation of broadband cavity enhanced absorption spectroscopy (BBCEAS) has been used to perform sensitive visible wavelength measurements on liquid-phase solutions in a 2 mm cuvette placed at normal incidence to the cavity mirrors. The overall experimental methodology was simple, low cost, and similar to conventional ultraviolet-visible absorption spectroscopy. The cavity was formed by two concave high reflectivity mirrors. Three mirror sets with nominal reflectivities (R) of R = 0.99, 0.9945, and 0.999 were used. The light source consisted of a high intensity red, green, blue, or white LED. The detector was a compact charge-coupled device (CCD) spectrograph. Measurements were made on the representative analytes, Ho(3+), and the dyes brilliant blue-R, sudan black, and coumarin 334 in appropriate solvents. Cavity enhancement factors (CEF) of up to 104 passes for the high reflectivity mirrors were obtained. The number of passes was limited by relatively high scattering and absorption losses in the cavity, of approximately 1 x 10(-2) per pass. Measurements over a wide wavelength range (420-670 nm) were also obtained in a single experiment with the white LED and the R = 0.99 mirror set for Ho(3+) and sudan black. The sensitivity of the experimental setup could be determined by calculating the minimum detectable change in the absorption coefficient alpha(min). The values ranged from 5.1 x 10(-5) to 1.2 x 10(-3) cm(-1). The limit of detection (LOD) for the strong absorber brilliant blue-R was 620 pM. A linear dynamic range of measurements of concentration over about two orders of magnitude was demonstrated. The overall sensitivity of the experimental setup compared very favorably with previous generally more experimentally complex and expensive liquid-phase cavity studies. Possible improvements to the technique and its applicability as an analytical tool are discussed.
منابع مشابه
Sensitive method for the kinetic measurement of trace species in liquids using cavity enhanced absorption spectroscopy with broad bandwidth supercontinuum radiation.
A novel spectrometer for the rapid and sensitive detection of liquid phase analytes at trace concentrations is presented. Broad bandwidth supercontinuum radiation was coupled into a linear optical cavity incorporating an intracavity liquid-sample cuvette. Cavity enhanced absorption spectra of trace species covering more than 300 nm were acquired on time scales of milliseconds. Single shot acqui...
متن کاملLiquid-phase broadband cavity enhanced absorption spectroscopy (BBCEAS) studies in a 20 cm cell.
Sensitive liquid-phase measurements have been made in a 20 cm cell using broadband cavity enhanced absorption spectroscopy (BBCEAS). The cavity was formed by two high reflectivity mirrors which were in direct contact with the liquid-phase analytes. Careful choice of solvent was required to minimise the effect of background solvent absorptions. Measurements were made on the broad absorber Sudan ...
متن کاملHigh sensitivity liquid phase measurements using broadband cavity enhanced absorption spectroscopy (BBCEAS) featuring a low cost webcam based prism spectrometer.
Cavity enhanced techniques enable high sensitivity absorption measurements in the liquid phase but are typically more complex, and much more expensive, to perform than conventional absorption methods. The latter attributes have so far prevented a wide spread use of these methods in the analytical sciences. In this study we demonstrate a novel BBCEAS instrument that is sensitive, yet simple and ...
متن کاملBroadband cavity-enhanced absorption spectroscopy in the ultraviolet spectral region for measurements of nitrogen dioxide and formaldehyde
Formaldehyde (CH2O) is the most abundant aldehyde in the atmosphere, and it strongly affects photochemistry through its photolysis. We describe simultaneous measurements of CH2O and nitrogen dioxide (NO2) using broadband cavity-enhanced absorption spectroscopy in the ultraviolet spectral region. The light source consists of a continuous-wave diode laser focused into a Xenon bulb to produce a pl...
متن کاملCavity-Enhanced Immunoassay Measurements in Microtiter Plates Using BBCEAS.
We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R ≥ 0.99 optical cavity was integrated with a motorized XY stage, which functioned as a receptacle for 96-well microtiter plates. The custom-built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied spectroscopy
دوره 61 6 شماره
صفحات -
تاریخ انتشار 2007